Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Laserman closed April 25, Thursday for Anzac Day Public Holiday! Call Us +61 8 9335 1718
FREE Shipping For Purchases Over $250 within Australia

Fluke 5615 Secondary Reference Temperature Standards,100 OHM, 90 BEND

SKU: 3002916
$2,909.00

Part Number

Checkout Secure
Need more info? Call us +61 8 9335 1718

6Great reasons to buy from us:

  • Image of If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.

    30 Days Return

    If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.
  • Image of Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

    Returns are Easy

    Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
  • Image of In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.

    Best Price Guarantee

    In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.
  • Image of We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.

    We guarantee your satisfaction

    We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.
  • Image of Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.

    100% Safe & Secure

    Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.
  • Image of Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

    Best Laser Warranties in the Business

    Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

Durable, accurate sensors for use in the factory, field or lab

 (item no. 3002916, 3002933, 3002940, 3002957, 3002969, 3002978, 3002984, 3376923)

  • Affordable wide-range accuracy
  • Calibrated accuracy ± 0.012 °C at 0 °C
  • Reference-grade platinum sensing element
  • NVLAP-accredited calibration included, lab code 200706-0

For years, you’ve relied on our 5612, 5613, and 5614 Secondary Reference Probes. These field-durable, lab-accurate PRTs have been replaced by the 5615, which comes with a NVLAP accredited calibration.

The 5615-12 (formerly Hart Scientific) is a Platinum Resistance Thermometer (PRT) with an Inconel™ 600 sheath that’s 305 mm (12 in) long and 6.35 mm (0.250 in) in diameter. It is a secondary reference temperature standard designed to bridge the gap between the highest laboratory standards and industrial or second-tier lab locations. It has accuracy of ± 0.012 °C at 0.01 °C.

The element is constructed of reference-grade platinum wire (99.999 % pure) for excellent stability. The wire is wound in a coil and placed in a mandrel where it’s uniformly supported in a manner that virtually eliminates hysteresis. The electrical configuration is a four-wire current-potential hookup that eliminate the effects of lead-wire resistance.

These Inconel™-sheathed probes have a fully supported sensing element, making them more durable than SPRTs. The element is protected in an ultrahigh-purity ceramic case with a hermetic glass seal to improve output stability by locking out moisture and contaminants.

This probe comes calibrated with ITS-90 coefficients, making it compatible with many excellent readout devices, including Fluke Calibration’s 1529 Chub-E4, 1560 Black Stack, and 1502A Tweener. It bridges the gap between a 100-ohm industrial RTD and an SPRT.

For those needing faster thermal response, or where diameter and immersion depth are problems, order the 5615-9 or 5615-6. These probes are excellent reference probes for comparison calibrations in a Fluke Calibration dry-well. The sheaths of the 5615-6 and 5615-9 are 4.76 mm (0.188 in) in diameter.

A printout of sensor resistance is provided in 1 °C increments for each probe. The 5615-9 and 5615-12 are calibrated from –196 °C to 420 °C. The 5615-6 is calibrated to 300 °C.

We’ve tested many of the probes on the market. We’ve used them in our manufacturing facility and tested them in the lab, and this is an excellent secondary standards PRT. Other instruments on the market are priced much higher, have lower stability, or are of lower quality.

Remember, these are reliable instruments and each probe comes with its own individual NVLAP-accredited calibration, lab code 200706-0.

Specifications

Temperature range
 
5615-12 and 5615-9: –200 °C to 420 °C
5615-6: –200 °C to 300 °C
Nominal resistance at 0 °C 100 Ω ± 0.10 Ω
Temperature coefficient 0.0039250 Ω/Ω/°C
Accuracy[1]
 
 
± 0.024 °C at –200 °C
± 0.012 °C at 0 °C
± 0.035 °C at 420 °CC
Short-term repeatability[2] ± 0.009 °C at 0.010 °C
Drift[3] ± 0.007 °C at 0.010 °C
Sensor length 28 mm (1.1 in)
Sensor location 6.9 mm ± 3.3 mm from tip (0.27 in ± 0.13 in)
Sheath dimensions 5615-6: 152 mm x 4.76 mm (6.0 in x 0.188 in)
5615-9: 229 mm x 4.76 mm (9.0 in x 0.188 in)
5615-12: 305 mm x 6.35 mm (12.0 in x 0.250 in)
Sheath diameter tolerance ± 0.127 mm (± 0.005 in)
Sheath material Inconel™ 600
Minimum insulation resistance 1000 MΩ at 23 °C
Transition junction temperature range[4] –50 °C to 200 °C
 
Transition junction dimensions 71 mm x 13 mm dia (2.8 in x 0.5 in)
Maximum immersion length
 
 
5615-6: 102 mm (4 in)
5615-9: 178 mm (7 in)
5615-12: 254 mm (10 in)
Response time[5] 9 seconds typical
Self heating (in 0 °C bath) 50 mW/°C
Lead-wire cable type PTFE insulated with PTFE jacket, 22 AWG
Lead-wire length 183 cm (72 in or 6 ft)
Lead-wire temperature range –50 °C to 200 °C
Calibration
 
 

NVLAP-accredited calibration included, lab code 200706-0. Please see calibration uncertainty table and its explanation of changeable uncertainties.

[1] Includes calibration and 100 hr drift (k=2)

[2] Three thermal cycles from min to max temp, includes hysteresis, 95 % confidence (k=2)

[3] After 100 hrs at max temp, 95 % confidence (k=2)

[4] Temperatures outside this range will cause irreparable damage. For best performance, transition junction should not be too hot to touch.

[5] Per ASTM E 644

NVLAP† Calibration Uncertainty

Temperature Expanded Uncertainty (k=2)
–196 °C 0.024 °C
–38 °C 0.011 °C
0 °C 0.010 °C
200 °C 0.018 °C
420 °C 0.029 °C

Note: Calibration uncertainties depend on the uncertainties of the lab performing the calibration. Subsequent calibrations of this probe performed with different processes, at different facilities, or with changed uncertainty statements may state different uncertainties. †Lab code 200706-0 ‡5615-6 excluded

 

Model Name Description
5615-6-X

Secondary Standard PRT, 4.76 mm x 152 mm (0.188 x 6.0 in), –200 °C to 300 °C, lead wire (cable) 6 ft

(17025 accredited calibration included. Traceable to NIST standards.)

X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs).

5615-9-X

Secondary Standard PRT, 4.76 mm x 229 mm (0.188 x 9.0 in), –200 °C to 420 °C,  lead wire (cable) 6 ft

(17025 accredited calibration included. Traceable to NIST standards.)

X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs).

5615-12-X

Secondary Standard PRT, 6.35 mm x 305 mm (0.250 x 12.0 in), –200 °C to 420 °C,  lead wire (cable) 6 ft

(17025 accredited calibration included. Traceable to NIST standards.)

X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs).

Accessories common to all models:

Accessory Description
2601

Probe Carrying Case, Plastic 

 

Product Manuals
application/pdf icon 5615 Platinum Resistance Thermometer User’s Guide (94.6 KB)
Brochures
application/pdf icon Free Reference PRT with Portable Bath Purchase Redemption Form (329.23 KB)
Application Notes
application/pdf icon Calculating Calibration Uncertainties in an Automated Temperature Calibration System (426.88 KB)
application/pdf icon Establishment of a Secondary Temperature Calibration Laboratory (3.09 MB)
application/pdf icon How to Calibrate an RTD or Platinum Resistance Thermometer (PRT) (652.16 KB)
application/pdf icon Kalibrieren eines RTD oder Platin-Widerstandsthermometers (PRT) (German) (828.03 KB)
application/pdf icon Comment étalonner unde sonde RTD ou sonde à résistance de platine (PRT) (French) (834.22 KB)
application/pdf icon Cómo calibrar una RTD o un sensor de temperatura (Spanish) (819.7 KB)
application/pdf icon Industrial temperature readout and probe selection guide (2.33 MB)
application/pdf icon Anleitung zur Auswahl von Temperaturanzeigegeräten und Messfühlern für den Industrieeinsatz (German) (585.2 KB)
application/pdf icon Guide de sélection des afficheurs et sondes de températures industrielles (French) (584.47 KB)
application/pdf icon Guía para la elección de sonda y lectura de temperatura industrial (Spanish) (581.27 KB)
application/pdf icon Руководство по выбору промышленных показаний и зонда температуры (Russian) (686.56 KB)
application/pdf icon Guia de seleção de instrumento de leitura e sonda de temperatura industrial (Portuguese) (580.6 KB)
application/pdf icon 工业测温仪和探头选型指南 (Chinese) (253.92 KB)
application/pdf icon Temperature Calibration Equipment: A Technician's Guide (1.62 MB)
application/pdf icon Temperature measurement and calibration: What every instrument technician should know (1.65 MB)
application/pdf icon Temperaturmessung und -kalibrierung (German) (650.54 KB)
application/pdf icon Mesure et étalonnage thermique (French) (655.57 KB)
application/pdf icon Medición y calibración de temperatura (Spanish) (651.42 KB)
application/pdf icon English: Thermocouple App Notes Series, 1 of 4 - Thermocouple Fundamentals (2.5 MB)
application/pdf icon Korean: 열전대 응용시리즈 첫번째 - 열전대의 기본사항 (2.28 MB)
application/pdf icon German: Thermocouple App Notes Series, 1 of 4 - Grundlagen zu Thermoelementen (2.22 MB)
application/pdf icon French: Thermocouple App Notes Series, 1 of 4 - L'essentiel des thermocouples (2.22 MB)
application/pdf icon Spanish: Thermocouple App Notes Series, 1 of 4 - Nociones básicas de los termopares (2.22 MB)
application/pdf icon Russian: Thermocouple App Notes Series, 1 of 4 - Основные сведения о термопаре (2.29 MB)
application/pdf icon English: Thermocouple App Notes Series, 2 of 4 - How to Select Thermocouple Calibration Equipment (2.51 MB)
application/pdf icon German: Thermocouple App Notes Series, 2 of 4 - Auswahl von Geräten zur Kalibrierung von Thermoelementen (2.21 MB)
application/pdf icon French: Thermocouple App Notes Series, 2 of 4 - Guide de sélection d'équipement d'étalonnage de thermocouple (2.21 MB)
application/pdf icon Russian: Thermocouple App Notes Series, 2 of 4 - Как выбрать оборудование для калибровки термопары (2.26 MB)
application/pdf icon Spanish: Thermocouple App Notes Series, 2 of 4 - Cómo elegir un equipo de calibración de termopares (2.21 MB)
application/pdf icon Why Use a Triple Point of Water? (1.19 MB)
application/pdf icon Does Immersion Depth Really Matter? (745.44 KB)
Data Sheets
application/pdf icon Automated 7380 Temperature Calibration Systems Technical Data (776.81 KB)
application/pdf icon Secondary Reference Temperature Standards Technical Data (572.5 KB)
Papers / Articles
application/pdf icon An Investigation into the Stability of Industrial Platinum Resistance Thermometers (262.44 KB)
Shipping This Item Ships from Fremantle, Perth, Western Australia
Please allow 2 - 10 days for your order to arrive.

Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

Returns are easy.

simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

Description

Durable, accurate sensors for use in the factory, field or lab

 (item no. 3002916, 3002933, 3002940, 3002957, 3002969, 3002978, 3002984, 3376923)

  • Affordable wide-range accuracy
  • Calibrated accuracy ± 0.012 °C at 0 °C
  • Reference-grade platinum sensing element
  • NVLAP-accredited calibration included, lab code 200706-0

For years, you’ve relied on our 5612, 5613, and 5614 Secondary Reference Probes. These field-durable, lab-accurate PRTs have been replaced by the 5615, which comes with a NVLAP accredited calibration.

The 5615-12 (formerly Hart Scientific) is a Platinum Resistance Thermometer (PRT) with an Inconel™ 600 sheath that’s 305 mm (12 in) long and 6.35 mm (0.250 in) in diameter. It is a secondary reference temperature standard designed to bridge the gap between the highest laboratory standards and industrial or second-tier lab locations. It has accuracy of ± 0.012 °C at 0.01 °C.

The element is constructed of reference-grade platinum wire (99.999 % pure) for excellent stability. The wire is wound in a coil and placed in a mandrel where it’s uniformly supported in a manner that virtually eliminates hysteresis. The electrical configuration is a four-wire current-potential hookup that eliminate the effects of lead-wire resistance.

These Inconel™-sheathed probes have a fully supported sensing element, making them more durable than SPRTs. The element is protected in an ultrahigh-purity ceramic case with a hermetic glass seal to improve output stability by locking out moisture and contaminants.

This probe comes calibrated with ITS-90 coefficients, making it compatible with many excellent readout devices, including Fluke Calibration’s 1529 Chub-E4, 1560 Black Stack, and 1502A Tweener. It bridges the gap between a 100-ohm industrial RTD and an SPRT.

For those needing faster thermal response, or where diameter and immersion depth are problems, order the 5615-9 or 5615-6. These probes are excellent reference probes for comparison calibrations in a Fluke Calibration dry-well. The sheaths of the 5615-6 and 5615-9 are 4.76 mm (0.188 in) in diameter.

A printout of sensor resistance is provided in 1 °C increments for each probe. The 5615-9 and 5615-12 are calibrated from –196 °C to 420 °C. The 5615-6 is calibrated to 300 °C.

We’ve tested many of the probes on the market. We’ve used them in our manufacturing facility and tested them in the lab, and this is an excellent secondary standards PRT. Other instruments on the market are priced much higher, have lower stability, or are of lower quality.

Remember, these are reliable instruments and each probe comes with its own individual NVLAP-accredited calibration, lab code 200706-0.

Specifications

Temperature range
 
5615-12 and 5615-9: –200 °C to 420 °C
5615-6: –200 °C to 300 °C
Nominal resistance at 0 °C 100 Ω ± 0.10 Ω
Temperature coefficient 0.0039250 Ω/Ω/°C
Accuracy[1]
 
 
± 0.024 °C at –200 °C
± 0.012 °C at 0 °C
± 0.035 °C at 420 °CC
Short-term repeatability[2] ± 0.009 °C at 0.010 °C
Drift[3] ± 0.007 °C at 0.010 °C
Sensor length 28 mm (1.1 in)
Sensor location 6.9 mm ± 3.3 mm from tip (0.27 in ± 0.13 in)
Sheath dimensions 5615-6: 152 mm x 4.76 mm (6.0 in x 0.188 in)
5615-9: 229 mm x 4.76 mm (9.0 in x 0.188 in)
5615-12: 305 mm x 6.35 mm (12.0 in x 0.250 in)
Sheath diameter tolerance ± 0.127 mm (± 0.005 in)
Sheath material Inconel™ 600
Minimum insulation resistance 1000 MΩ at 23 °C
Transition junction temperature range[4] –50 °C to 200 °C
 
Transition junction dimensions 71 mm x 13 mm dia (2.8 in x 0.5 in)
Maximum immersion length
 
 
5615-6: 102 mm (4 in)
5615-9: 178 mm (7 in)
5615-12: 254 mm (10 in)
Response time[5] 9 seconds typical
Self heating (in 0 °C bath) 50 mW/°C
Lead-wire cable type PTFE insulated with PTFE jacket, 22 AWG
Lead-wire length 183 cm (72 in or 6 ft)
Lead-wire temperature range –50 °C to 200 °C
Calibration
 
 

NVLAP-accredited calibration included, lab code 200706-0. Please see calibration uncertainty table and its explanation of changeable uncertainties.

[1] Includes calibration and 100 hr drift (k=2)

[2] Three thermal cycles from min to max temp, includes hysteresis, 95 % confidence (k=2)

[3] After 100 hrs at max temp, 95 % confidence (k=2)

[4] Temperatures outside this range will cause irreparable damage. For best performance, transition junction should not be too hot to touch.

[5] Per ASTM E 644

NVLAP† Calibration Uncertainty

Temperature Expanded Uncertainty (k=2)
–196 °C 0.024 °C
–38 °C 0.011 °C
0 °C 0.010 °C
200 °C 0.018 °C
420 °C 0.029 °C

Note: Calibration uncertainties depend on the uncertainties of the lab performing the calibration. Subsequent calibrations of this probe performed with different processes, at different facilities, or with changed uncertainty statements may state different uncertainties. †Lab code 200706-0 ‡5615-6 excluded

 

Model Name Description
5615-6-X

Secondary Standard PRT, 4.76 mm x 152 mm (0.188 x 6.0 in), –200 °C to 300 °C, lead wire (cable) 6 ft

(17025 accredited calibration included. Traceable to NIST standards.)

X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs).

5615-9-X

Secondary Standard PRT, 4.76 mm x 229 mm (0.188 x 9.0 in), –200 °C to 420 °C,  lead wire (cable) 6 ft

(17025 accredited calibration included. Traceable to NIST standards.)

X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs).

5615-12-X

Secondary Standard PRT, 6.35 mm x 305 mm (0.250 x 12.0 in), –200 °C to 420 °C,  lead wire (cable) 6 ft

(17025 accredited calibration included. Traceable to NIST standards.)

X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs).

Accessories common to all models:

Accessory Description
2601

Probe Carrying Case, Plastic 

 

Product Manuals
application/pdf icon 5615 Platinum Resistance Thermometer User’s Guide (94.6 KB)
Brochures
application/pdf icon Free Reference PRT with Portable Bath Purchase Redemption Form (329.23 KB)
Application Notes
application/pdf icon Calculating Calibration Uncertainties in an Automated Temperature Calibration System (426.88 KB)
application/pdf icon Establishment of a Secondary Temperature Calibration Laboratory (3.09 MB)
application/pdf icon How to Calibrate an RTD or Platinum Resistance Thermometer (PRT) (652.16 KB)
application/pdf icon Kalibrieren eines RTD oder Platin-Widerstandsthermometers (PRT) (German) (828.03 KB)
application/pdf icon Comment étalonner unde sonde RTD ou sonde à résistance de platine (PRT) (French) (834.22 KB)
application/pdf icon Cómo calibrar una RTD o un sensor de temperatura (Spanish) (819.7 KB)
application/pdf icon Industrial temperature readout and probe selection guide (2.33 MB)
application/pdf icon Anleitung zur Auswahl von Temperaturanzeigegeräten und Messfühlern für den Industrieeinsatz (German) (585.2 KB)
application/pdf icon Guide de sélection des afficheurs et sondes de températures industrielles (French) (584.47 KB)
application/pdf icon Guía para la elección de sonda y lectura de temperatura industrial (Spanish) (581.27 KB)
application/pdf icon Руководство по выбору промышленных показаний и зонда температуры (Russian) (686.56 KB)
application/pdf icon Guia de seleção de instrumento de leitura e sonda de temperatura industrial (Portuguese) (580.6 KB)
application/pdf icon 工业测温仪和探头选型指南 (Chinese) (253.92 KB)
application/pdf icon Temperature Calibration Equipment: A Technician's Guide (1.62 MB)
application/pdf icon Temperature measurement and calibration: What every instrument technician should know (1.65 MB)
application/pdf icon Temperaturmessung und -kalibrierung (German) (650.54 KB)
application/pdf icon Mesure et étalonnage thermique (French) (655.57 KB)
application/pdf icon Medición y calibración de temperatura (Spanish) (651.42 KB)
application/pdf icon English: Thermocouple App Notes Series, 1 of 4 - Thermocouple Fundamentals (2.5 MB)
application/pdf icon Korean: 열전대 응용시리즈 첫번째 - 열전대의 기본사항 (2.28 MB)
application/pdf icon German: Thermocouple App Notes Series, 1 of 4 - Grundlagen zu Thermoelementen (2.22 MB)
application/pdf icon French: Thermocouple App Notes Series, 1 of 4 - L'essentiel des thermocouples (2.22 MB)
application/pdf icon Spanish: Thermocouple App Notes Series, 1 of 4 - Nociones básicas de los termopares (2.22 MB)
application/pdf icon Russian: Thermocouple App Notes Series, 1 of 4 - Основные сведения о термопаре (2.29 MB)
application/pdf icon English: Thermocouple App Notes Series, 2 of 4 - How to Select Thermocouple Calibration Equipment (2.51 MB)
application/pdf icon German: Thermocouple App Notes Series, 2 of 4 - Auswahl von Geräten zur Kalibrierung von Thermoelementen (2.21 MB)
application/pdf icon French: Thermocouple App Notes Series, 2 of 4 - Guide de sélection d'équipement d'étalonnage de thermocouple (2.21 MB)
application/pdf icon Russian: Thermocouple App Notes Series, 2 of 4 - Как выбрать оборудование для калибровки термопары (2.26 MB)
application/pdf icon Spanish: Thermocouple App Notes Series, 2 of 4 - Cómo elegir un equipo de calibración de termopares (2.21 MB)
application/pdf icon Why Use a Triple Point of Water? (1.19 MB)
application/pdf icon Does Immersion Depth Really Matter? (745.44 KB)
Data Sheets
application/pdf icon Automated 7380 Temperature Calibration Systems Technical Data (776.81 KB)
application/pdf icon Secondary Reference Temperature Standards Technical Data (572.5 KB)
Papers / Articles
application/pdf icon An Investigation into the Stability of Industrial Platinum Resistance Thermometers (262.44 KB)

Shipping

Shipping This item ships to

Delivery & Returns

Please allow 2 - 10 days for your order to arrive.

Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

Returns are easy.

simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

Reviews

Fluke 5615 Secondary Reference Temperature Standards,100 OHM, 90 BEND

Fluke 5615 Secondary Reference Temperature Standards,100 OHM, 90 BEND

$2,909.00

Part Number

Fluke 5615 Secondary Reference Temperature Standards,100 OHM, 90 BEND

Fluke 5615 Secondary Reference Temperature Standards,100 OHM, 90 BEND

$2,909.00

Part Number

Recently viewed products