Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Laserman closed April 25, Thursday for Anzac Day Public Holiday! Call Us +61 8 9335 1718
FREE Shipping For Purchases Over $250 within Australia

Fluke 6109A / 7109A Portable Calibration Baths

SKU: 4757536
$17,378.00

(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )

Checkout Secure
Need more info? Call us +61 8 9335 1718

6Great reasons to buy from us:

  • Image of If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.

    30 Days Return

    If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.
  • Image of Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

    Returns are Easy

    Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
  • Image of In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.

    Best Price Guarantee

    In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.
  • Image of We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.

    We guarantee your satisfaction

    We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.
  • Image of Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.

    100% Safe & Secure

    Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.
  • Image of Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

    Best Laser Warranties in the Business

    Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

6109A / 7109A Portable Calibration Baths

(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )

(item no. 4757536, 4757551, 4757572, 4757597)

Now there are portable calibration baths (6109A & 7109A) designed with the process manufacturing professional in mind. Process manufacturing plants for pharmaceuticals, biotechnology, and food production utilise many sanitary temperature sensors that require regular calibration. Production must stop during temperature sensor calibration. Therefore, more calibration throughput means less plant downtime. And in businesses where even a few tenths of a degree Celsius can cost thousands of dollars in ruined product, temperature accuracy is crucial to maintaining quality.

The Fluke Calibration 6109A and 7109A Portable Calibration Baths are liquid baths that let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other portable baths in this class. Larger than micro baths, up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ± 0.1 °C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges.

Two bath models cover a wide temperature range: 35 °C to 250 °C for the 6109A and -25 °C to 140 °C for the 7109A. Each model offers a “-P” version that includes process electronics for connecting an external reference probe.

Professionals working in clean process industries, including facilities managers, production engineers and calibration technicians, prefer these baths for a variety of reasons.

Facilities managers who need to meet U.S. FDA and ISO clean room standards like the baths’ stainless steel casing that stands up to harsh cleaning solutions. They depend on the 6109A and 7109A to help maintain the accuracy of the plant’s temperature sensors, thus reducing the possibility of an expensive product batch loss.

 

FEATURES

  • Calibrate up to four tri-clamp sanitary sensors at the same time
  • Wide temperature ranges cover most process applications:
    • 6109A: 35 °C to 250 °C
    • 7109A: –25 °C to 140 °C
  • Excellent display accuracy of ±0.1 °C provides 4:1 test uncertainty ratio (TUR) for critical applications
  • Easy to transport up stairs and across catwalks
  • Stainless steel casing withstands harsh sterilising chemicals and is rust proof
  • Easy to use and maintain
  • Global Fluke support and service

 

Calibrate more sanitary sensors at a time – with confidence

The 6109A and 7109A baths calibrate most temperature sensor applications used in clean process manufacturing, including pharmaceutical bioreactors (-10 C to 100 °C), chemical reactors (200 °C), steam-in-place process (122 °C to 140 °C), autoclave sterilization (120 °C to 135 °C), food storage freezers (-25 °C), and food processing (0 °C to 220 °C).

A large tank volume (112 mm square tank opening x 154 mm depth) lets you immerse up to four sanitary sensors at the same time. Calibrate a batch of odd shaped temperature sensors of varying lengths and diameters, and still have room for a reference thermometer. Fast heating and cooling times let you get the job done without spending a lot of time waiting for the bath to come to temperature and stabilize. Increase your sanitary sensor calibration throughput and decrease expensive production downtime.

Excellent system display accuracy of ± 0.1 °C. Accuracy covers all sources of error including calibration uncertainty, stability, uniformity, and repeatability. NVLAP accredited calibration is included standard. Fluke Calibration’s high metrological standards and conservative specifications mean you can have confidence in the measurements you make with the 6109A and 7109A Portable Calibration Baths.
 


Easy to use and maintain

Each bath features a large colour display that indicates date and time, bath fluid temperature, setpoint temperature, control indicator when the fluid is at setpoint, and heating status. A ready indicator changes colour from amber to green, giving you 360-degree visual indication when the bath fluid has reached its setpoint temperature and is ready for you to start making measurements.

A hot warning indicator lights up if the fluid temperature reaches above 60 °C, warning the operator that the bath fluid and tank area are hot and should not be touched.

An adjustable probe fixture holds up to four tri-clamp sensors securely inside the tank opening during calibration. An optional single probe clamp kit holds a reference probe.

Fluid spills create mess and potential safety hazards. The 6109A and 7109A include an overflow tube that directs excess bath fluid into an optional overflow container. A drain tube makes it easy to remove bath fluid for replacement or transport.

I own a Fluke Calibration Micro-Bath. Why do I need a 6109A or 7109A bath?

If you already own a Fluke Calibration Micro-Bath or dry-block calibrator, thank you for being a customer! We hope you are enjoying the portability and stability of these popular products.

However, there are a few reasons why you should consider adding a 6109A or 7109A bath:

  • Errors of just a few tenths of a degree Celsius can cause expensive losses in ruined product. The 6109A and 7109A baths are twice as accurate as a Micro-Bath, helping you to reduce this risk.
  • The 6109A and 7109A have four times the calibration throughput of a Micro-Bath, which can only calibrate a single tri-clamp sensor at a time.
  • They're made with materials that don't harbour bacteria. Their stainless steel panels and tank are easy to clean and rust resistant--perfect for clean room use.

We hope you will continue to use your Fluke Calibration Micro-Bath for many years to come. The 6109A or 7109A baths will also serve you well if you need the throughput, accuracy, and clean room readiness that they provide. 

 

MODEL SPECIFICATIONS

Model Name Description
6109A

Portable Calibration Bath, 35 °C to 250 °C

6109A-P

Portable Calibration with Process Electronics, 35 °C to 250 °C

7109A

Portable Calibration Bath, -25 °C to 140 °C

7109A-P

Portable Calibration Bath with Process Electronics, -25 °C to 140 °C

 

GENERAL SPECIFICATIONS

Size Height: 382 mm (15 in)
Width: 242 mm (9.5 in)
Depth: 400 mm (15.7 in)
Weight 6109A: 16 kg (35 lb)
7109A: 20 kg (44 lb)
Power requirements 100 V to 115 V (± 10 %) 50/60 Hz, 1150 W
200 V to 230 V (± 10 %) 50/60 Hz, 1150 W
Fluid volume 2.5 liters (0.66 gallons)
Fluid working area 75 mm x 75 mm (3 in x 3 in)
Maximum fluid depth 154 mm (6.1 in)
Factory calibration Traceable NVLAP-accredited calibration included

 

Temperature specifications
The temperature specifications describe the Absolute Instrumental Uncertainty at 95 % level of confidence (coverage factor k = 2) within one year from calibration. The specifications include environmental temperature effects from 13 °C to 33 °C.
  6109A 7109A
Range (at 25 °C ambient temperature) 35 °C to 250 °C –25 °C to 140 °C (–15 °C cover off)
Accuracy (maximum permissible error) 0.1 °C 0.1 °C
Display resolution 0.01 °, 0.001°
0.01 °, 0.001°
Stability 0.015 °C 0.01 °C
Typical uniformity 0.03 °C up to 200 °C
0.04 °C above 200 °C
0.02 °C
Repeatability 0.04 °C 0.04 °C
Typical heating time 35 °C to 100 °C: 25 minutes
100 °C to 250 °C: 45 minutes
–25 °C to 25 °C: 35 minutes
25 °C to 140 °C: 55 minutes
Typical cooling time 250 °C to 100 °C: 35 minutes
100 °C to 35 °C: 55 minutes
140 °C to 25 °C: 45 minutes
25 °C to –25 °C: 75 minutes
Typical settling time 15 minutes 10 minutes

 

Process Input Module specifications (-P models)
The Input Module specifications describe the Absolute Instrumental Uncertainty at 95 % level of confidence (coverage factor k = 2) within one year from calibration. The specifications include calibration uncertainty, linearity, repeatability, resolution, stability, and environmental temperature effects from 13 °C to 33 °C.
Function Range Accuracy (Maximum Permissible Error)
Reference input resistance 0 Ω to 42 Ω
42 Ω to 400 Ω
0.0025 Ω
0.006 %
Reference input temperature -25 °C to 250 °C 0.007 % + 0.015 °C
Resistance sensing current 1 mA 8 %
DUT 4-wire resistance 0 Ω to 31 Ω
31 Ω to 400 Ω
0.0025 Ω
0.008%
DUT 3-wire resistance accuracy 0 Ω to 400 Ω 0.12 Ω
Thermocouple mV -10 mV to 100 mV 0.025 % + 0.01 mV
Reference junction temperature 0 °C to 40 °C 0.35 °C
Thermocouple temperature -25 °C to 250 °C J: 0.44 °C
E: 0.44 °C
L: 0.42 °C
K: 0.49 °C
N: 0.57 °C
U: 0.48 °C
T: 0.53 °C
M: 0.48 °C
0 °C to 250 °C R: 1.92 °C
D: 1.12 °C
S: 1.88 °C
G/W: 3.34 °C
C: 0.84 °C
mA range 0 mA to 22 mA 0.02 % + 0.002 mA
Loop power 24 V dc ± 6 V

 


Accessories common to all models:

Accessory Description
7109-2013-1

Stainless Steel Transport Cover 

7109-2013-2

Stainless Steel Probe Access Cover 

7109-2027

Adjustable Probe Holding Fixture 

7109-2051

Single Probe Clamp Kit

7109-2080

Fluid Overflow Kit 

7109-CASE

Carrying Case 

5012-3.8L

Silicone Oil Type 200.10, 3.8 liters (1 gal)

5014-3.8L

Silicone Oil Type 200.50, 3.8 liters (1 gal)

 

 

Shipping This Item Ships from Fremantle, Perth, Western Australia
Please allow 2 - 10 days for your order to arrive.

Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

Returns are easy.

simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

Description

6109A / 7109A Portable Calibration Baths

(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )

(item no. 4757536, 4757551, 4757572, 4757597)

Now there are portable calibration baths (6109A & 7109A) designed with the process manufacturing professional in mind. Process manufacturing plants for pharmaceuticals, biotechnology, and food production utilise many sanitary temperature sensors that require regular calibration. Production must stop during temperature sensor calibration. Therefore, more calibration throughput means less plant downtime. And in businesses where even a few tenths of a degree Celsius can cost thousands of dollars in ruined product, temperature accuracy is crucial to maintaining quality.

The Fluke Calibration 6109A and 7109A Portable Calibration Baths are liquid baths that let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other portable baths in this class. Larger than micro baths, up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ± 0.1 °C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges.

Two bath models cover a wide temperature range: 35 °C to 250 °C for the 6109A and -25 °C to 140 °C for the 7109A. Each model offers a “-P” version that includes process electronics for connecting an external reference probe.

Professionals working in clean process industries, including facilities managers, production engineers and calibration technicians, prefer these baths for a variety of reasons.

Facilities managers who need to meet U.S. FDA and ISO clean room standards like the baths’ stainless steel casing that stands up to harsh cleaning solutions. They depend on the 6109A and 7109A to help maintain the accuracy of the plant’s temperature sensors, thus reducing the possibility of an expensive product batch loss.

 

FEATURES

  • Calibrate up to four tri-clamp sanitary sensors at the same time
  • Wide temperature ranges cover most process applications:
    • 6109A: 35 °C to 250 °C
    • 7109A: –25 °C to 140 °C
  • Excellent display accuracy of ±0.1 °C provides 4:1 test uncertainty ratio (TUR) for critical applications
  • Easy to transport up stairs and across catwalks
  • Stainless steel casing withstands harsh sterilising chemicals and is rust proof
  • Easy to use and maintain
  • Global Fluke support and service

 

Calibrate more sanitary sensors at a time – with confidence

The 6109A and 7109A baths calibrate most temperature sensor applications used in clean process manufacturing, including pharmaceutical bioreactors (-10 C to 100 °C), chemical reactors (200 °C), steam-in-place process (122 °C to 140 °C), autoclave sterilization (120 °C to 135 °C), food storage freezers (-25 °C), and food processing (0 °C to 220 °C).

A large tank volume (112 mm square tank opening x 154 mm depth) lets you immerse up to four sanitary sensors at the same time. Calibrate a batch of odd shaped temperature sensors of varying lengths and diameters, and still have room for a reference thermometer. Fast heating and cooling times let you get the job done without spending a lot of time waiting for the bath to come to temperature and stabilize. Increase your sanitary sensor calibration throughput and decrease expensive production downtime.

Excellent system display accuracy of ± 0.1 °C. Accuracy covers all sources of error including calibration uncertainty, stability, uniformity, and repeatability. NVLAP accredited calibration is included standard. Fluke Calibration’s high metrological standards and conservative specifications mean you can have confidence in the measurements you make with the 6109A and 7109A Portable Calibration Baths.
 


Easy to use and maintain

Each bath features a large colour display that indicates date and time, bath fluid temperature, setpoint temperature, control indicator when the fluid is at setpoint, and heating status. A ready indicator changes colour from amber to green, giving you 360-degree visual indication when the bath fluid has reached its setpoint temperature and is ready for you to start making measurements.

A hot warning indicator lights up if the fluid temperature reaches above 60 °C, warning the operator that the bath fluid and tank area are hot and should not be touched.

An adjustable probe fixture holds up to four tri-clamp sensors securely inside the tank opening during calibration. An optional single probe clamp kit holds a reference probe.

Fluid spills create mess and potential safety hazards. The 6109A and 7109A include an overflow tube that directs excess bath fluid into an optional overflow container. A drain tube makes it easy to remove bath fluid for replacement or transport.

I own a Fluke Calibration Micro-Bath. Why do I need a 6109A or 7109A bath?

If you already own a Fluke Calibration Micro-Bath or dry-block calibrator, thank you for being a customer! We hope you are enjoying the portability and stability of these popular products.

However, there are a few reasons why you should consider adding a 6109A or 7109A bath:

  • Errors of just a few tenths of a degree Celsius can cause expensive losses in ruined product. The 6109A and 7109A baths are twice as accurate as a Micro-Bath, helping you to reduce this risk.
  • The 6109A and 7109A have four times the calibration throughput of a Micro-Bath, which can only calibrate a single tri-clamp sensor at a time.
  • They're made with materials that don't harbour bacteria. Their stainless steel panels and tank are easy to clean and rust resistant--perfect for clean room use.

We hope you will continue to use your Fluke Calibration Micro-Bath for many years to come. The 6109A or 7109A baths will also serve you well if you need the throughput, accuracy, and clean room readiness that they provide. 

 

MODEL SPECIFICATIONS

Model Name Description
6109A

Portable Calibration Bath, 35 °C to 250 °C

6109A-P

Portable Calibration with Process Electronics, 35 °C to 250 °C

7109A

Portable Calibration Bath, -25 °C to 140 °C

7109A-P

Portable Calibration Bath with Process Electronics, -25 °C to 140 °C

 

GENERAL SPECIFICATIONS

Size Height: 382 mm (15 in)
Width: 242 mm (9.5 in)
Depth: 400 mm (15.7 in)
Weight 6109A: 16 kg (35 lb)
7109A: 20 kg (44 lb)
Power requirements 100 V to 115 V (± 10 %) 50/60 Hz, 1150 W
200 V to 230 V (± 10 %) 50/60 Hz, 1150 W
Fluid volume 2.5 liters (0.66 gallons)
Fluid working area 75 mm x 75 mm (3 in x 3 in)
Maximum fluid depth 154 mm (6.1 in)
Factory calibration Traceable NVLAP-accredited calibration included

 

Temperature specifications
The temperature specifications describe the Absolute Instrumental Uncertainty at 95 % level of confidence (coverage factor k = 2) within one year from calibration. The specifications include environmental temperature effects from 13 °C to 33 °C.
  6109A 7109A
Range (at 25 °C ambient temperature) 35 °C to 250 °C –25 °C to 140 °C (–15 °C cover off)
Accuracy (maximum permissible error) 0.1 °C 0.1 °C
Display resolution 0.01 °, 0.001°
0.01 °, 0.001°
Stability 0.015 °C 0.01 °C
Typical uniformity 0.03 °C up to 200 °C
0.04 °C above 200 °C
0.02 °C
Repeatability 0.04 °C 0.04 °C
Typical heating time 35 °C to 100 °C: 25 minutes
100 °C to 250 °C: 45 minutes
–25 °C to 25 °C: 35 minutes
25 °C to 140 °C: 55 minutes
Typical cooling time 250 °C to 100 °C: 35 minutes
100 °C to 35 °C: 55 minutes
140 °C to 25 °C: 45 minutes
25 °C to –25 °C: 75 minutes
Typical settling time 15 minutes 10 minutes

 

Process Input Module specifications (-P models)
The Input Module specifications describe the Absolute Instrumental Uncertainty at 95 % level of confidence (coverage factor k = 2) within one year from calibration. The specifications include calibration uncertainty, linearity, repeatability, resolution, stability, and environmental temperature effects from 13 °C to 33 °C.
Function Range Accuracy (Maximum Permissible Error)
Reference input resistance 0 Ω to 42 Ω
42 Ω to 400 Ω
0.0025 Ω
0.006 %
Reference input temperature -25 °C to 250 °C 0.007 % + 0.015 °C
Resistance sensing current 1 mA 8 %
DUT 4-wire resistance 0 Ω to 31 Ω
31 Ω to 400 Ω
0.0025 Ω
0.008%
DUT 3-wire resistance accuracy 0 Ω to 400 Ω 0.12 Ω
Thermocouple mV -10 mV to 100 mV 0.025 % + 0.01 mV
Reference junction temperature 0 °C to 40 °C 0.35 °C
Thermocouple temperature -25 °C to 250 °C J: 0.44 °C
E: 0.44 °C
L: 0.42 °C
K: 0.49 °C
N: 0.57 °C
U: 0.48 °C
T: 0.53 °C
M: 0.48 °C
0 °C to 250 °C R: 1.92 °C
D: 1.12 °C
S: 1.88 °C
G/W: 3.34 °C
C: 0.84 °C
mA range 0 mA to 22 mA 0.02 % + 0.002 mA
Loop power 24 V dc ± 6 V

 


Accessories common to all models:

Accessory Description
7109-2013-1

Stainless Steel Transport Cover 

7109-2013-2

Stainless Steel Probe Access Cover 

7109-2027

Adjustable Probe Holding Fixture 

7109-2051

Single Probe Clamp Kit

7109-2080

Fluid Overflow Kit 

7109-CASE

Carrying Case 

5012-3.8L

Silicone Oil Type 200.10, 3.8 liters (1 gal)

5014-3.8L

Silicone Oil Type 200.50, 3.8 liters (1 gal)

 

 

Shipping

Shipping This item ships to

Delivery & Returns

Please allow 2 - 10 days for your order to arrive.

Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

Returns are easy.

simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

Reviews

Fluke 6109A / 7109A Portable Calibration Baths

Fluke 6109A / 7109A Portable Calibration Baths

$17,378.00
Fluke 6109A / 7109A Portable Calibration Baths

Fluke 6109A / 7109A Portable Calibration Baths

$17,378.00

Recently viewed products