Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Laserman closed April 25, Thursday for Anzac Day Public Holiday! Call Us +61 8 9335 1718
FREE Shipping For Purchases Over $250 within Australia

Fluke 120B Series Industrial Scopemeter Hand Held Oscilloscope

SKU: 4755680
$3,048.00

Part Number

Checkout Secure
Need more info? Call us +61 8 9335 1718

6Great reasons to buy from us:

  • Image of If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.

    30 Days Return

    If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.
  • Image of Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

    Returns are Easy

    Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
  • Image of In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.

    Best Price Guarantee

    In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.
  • Image of We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.

    We guarantee your satisfaction

    We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.
  • Image of Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.

    100% Safe & Secure

    Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.
  • Image of Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

    Best Laser Warranties in the Business

    Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

(item no. 4755680, 4755927, 4755768, 4756005, 4755841, 4756087)

Key features

  • Dual-input digital oscilloscope and multimeter in a ScopeMeter® test tool
  • Available with a 40 MHz or 20 MHz oscilloscope bandwidth
  • Features Connect-and-View™ trigger simplicity for hands-off operation
  • Includes IntellaSet™ technology to automatically and intelligently adjust numerical readout based on measured signal
  • Provides a dual-input waveform and meter reading recorder for trending data over extended periods

Product overview: Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes

Simplified testing, more insight and faster electro-mechanical troubleshooting

The compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.

*Not all models are available in all countries. Check with your local Fluke representative.

Other useful features:

  • Features two 5,000-count True-RMS digital multimeters
  • Offers recorder Event Detect to capture elusive intermittent signals on repetitive waveforms up to 4 kHz
  • Comes with shielded test leads for oscilloscope, resistance and continuity measurements
  • Features resistance, continuity, diode, and capacitance meter measurements
  • Performs power measurements (W, VA, VAR, PF, DPF, Hz)
  • Measures voltage, current and power harmonics
  • Check Industrial networks with BusHealth physical layer tests against defined reference levels (125B only)
  • Allows you to save and recall data and instrument setups
  • Includes FlukeView® ScopeMeter® software for Windows®
  • Features a rugged design to withstand 3g vibration, 30g shock, and rated IP51 according to EN/IEC60529
  • Runs on a Li-Ion rechargeable battery providing seven-hours operation (with four-hour charge time)
  • Features highest safety rating in the industry: safety rated for CAT IV 600 V

Specifications: Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes

Oscilloscope mode
Vertical
Frequency response - dc coupled Without probes and test leads (with BB120) 123B: dc to 20 MHz (-3 dB)
124B and 125B: dc to 40 MHz (-3 dB)
With STL120-IV 1:1 shielded test leads DC to 12.5 MHz (-3 dB) / dc to 20 MHz (-6 dB)
With VP41 10:1 Probe 123B: dc to 20MHz (-3 dB)
124B and 125B: dc to 40 MHz (-3 dB)
Frequency response - ac coupled (lf roll off) Without probes and test leads <10 Hz (-3 dB)
With STL120-IV 1:1 shielded test leads <10 Hz (-3 dB)
With VP41 10:1 Probe <10 Hz (-3 dB)
Rise time, excluding probes, 
test leads
123B <17.5 ns
124B and 125B <8.75 ns
Input impedance Without probes and test leads 1 MΩ//20 pF
With BB120 1 MΩ//24 pF
With STL120-IV 1:1 shielded test leads 1 MΩ//230 pF
With VP41 10:1 Probe 5 MΩ//15.5 pF
Sensitivity 5 mV to 200 V/div
Analog bandwidth limiter 10 kHz
Display modes A, -A, B, -B
Max. input voltage A and B Direct, with test leads, or with VP41 Probe 600 Vrms Cat IV, 750 Vrms maximum voltage.
With BB120 600 Vrms
Max. floating voltage, from any terminal to ground 600 Vrms Cat IV, 750 Vrms up to 400Hz
Horizontal
Scope modes Normal, Single, Roll
Ranges (normal) Equivalent sampling 123B: 20 ns to 500 ns/div,
124B and 125B: 10 ns to 500 ns/div
Real time sampling 1 μs to 5 s/div
Single (real time) 1 μs to 5 s/div
Roll (real time) 1s to 60 s/div
Sampling rate (for both channels simultaneously) Equivalent sampling (repetitive signals) Up to 4 GS/s
Real time sampling 1 μs to 60 s/div 40 MS/s
 
Trigger
Screen update Free run, on trigger
Source A, B
Sensitivity A and B @ DC to 5 MHz 0.5 divisions or 5 mV
@ 40 MHz 123B: 4 divisions
124B and 125B: 1.5 divisions
@ 60 MHz 123B: N/A
124B and 125B: 4 divisions
Slope Positive, negative
 
Advanced scope functions
Display modes Normal Captures up to 25 ns glitches and displays analog-like persistence waveform
Smooth Suppresses noise from a waveform
Glitch off Does not capture glitches between samples
Envelope Records and displays the minimum and maximum of waveforms over time
Auto set (Connect-and-View™) Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.
 
Dual input meter
The accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C.
Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe  uncertainty +1%. More than one waveform period must be visible on the screen.
 
Input A and input B
DC voltage (VDC)
Ranges 500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy ±(0.5% +5 counts)
Common mode rejection (CMRR) >100 dB @ dc, >60 dB @ 50, 60, or 400 Hz
Full scale reading 5000 counts
True-rms voltages (V ac and V ac+dc)
Ranges 500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy for 5% to 100% of range (DC coupled) DC to 60 Hz (V ac+dc) ±(1% +10 counts)
1 Hz to 60 Hz (V ac) ±(1% +10 counts)
Accuracy for 5% to 100% of range (AC or dc coupled) 60 Hz to 20 kHz ±(2.5% +15 counts)
DC rejection (only VAC) >50 dB
Common mode rejection (CMRR) >100 dB @ dc
>60 dB @ 50, 60, or 400 Hz
Full scale reading 5000 counts, reading is independent of any signal crest factor.
Peak
Modes Max peak, Min peak, or pk-to-pk
Ranges 500 mV, 5 V, 50 V, 500 V, 2200 V
Accuracy Accuracy Max peak or Min peak 5% of full scale
Accuracy Peak-to-Peak 10% of full scale
Full scale reading 500 counts
Frequency (Hz)
Ranges 123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz
124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz
Frequency range 15 Hz (1 Hz) to 50 MHz in continuous autoset
Accuracy @1 Hz to 1 MHz ±(0.5% +2 counts)
Full scale reading 10,000 counts
RPM
Max reading 50.00 kRPM
Accuracy ±(0.5% +2 counts)
Duty cycle (PULSE)
Range 2% to 98%
Frequency range 15 Hz (1 Hz) to 30 MHz in continuous autoset
Pulse width (PULSE)
Frequency range 15 Hz (1 Hz) to 30 MHz in continuous autoset
Full scale reading 1000 counts
Amperes (AMP)
With current clamp Ranges Same as V dc, V ac, V ac+dc, or PEAK
Scale factors 0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA
Accuracy Same as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty)
Temperature (TEMP) with optional temperature probe
Range 200 °C/div (200 °F/div)
Scale factor 1 mV/°C and 1 mV/°F
Accuracy As V dc (add temp. probe uncertainty)
Decibel (dB)
0 dBV 1 V
0 dBm (600 Ω /50 Ω) 1 mW referenced to 600 Ω or 50 Ω
dB on V dc, V ac, or Vac+dc
Full scale reading 1000 counts
Crest factor (CREST)
Range 1 to 10
Full scale reading 90 Counts
Phase
Modes A to B, B to A
Range 0 to 359 degrees
Resolution 1 degree
Power (125B only)
Configurations 1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only)
Power factor (PF) Ratio between watts and VA range - 0.00 to 1.00
Watt RMS reading of multiplying corresponding samples of input A (volts) and input B (amperes)
Full scale reading 999 counts
VA Vrms x Arms
Full scale reading 999 counts
VA reactive (var) √((VA)2-W2)
Full scale reading 999 counts
Vpwm
Purpose To measure on pulse width modulated signals, like motor drive inverter outputs
Principle Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency
Accuracy As Vrms for sinewave signals
 
Input A to common
Ohm (Ω)
Ranges 123B and 124B 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
125B 50 Ω, 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
Accuracy ±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts)
Full scale reading 50 Ω to 5 MΩ - 5000 counts, 30 MΩ - 3000 counts
Measurement current 0.5 mA to 50 nA, decreases with increasing ranges
Open circuit voltage <4 V
Continuity (Cont)
Beep <(30 Ω ±5 Ω) in 50 Ω range
Measurement current 0.5 mA
Detection of shorts of ≥1 ms
Diode
Measurement voltage @0.5 mA >2.8 V
@open circuit <4 V
Measurement current 0.5 mA
Polarity + on input A, - on COM
Capacitance (CAP)
Ranges 50 nF, 500 nF, 5 μF, 50 μF, 500 μF
Full scale reading 5000 counts
Measurement current 500 nA to 0.5 mA, increases with increasing ranges
 
Advanced meter functions
Zero Set Set actual value to reference
AutoHold (on A) Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.
Fixed decimal point Activated by using attenuation keys
 
Cursor Readout (124B and 125B)
Sources A, B
Single vertical line Average, min and max readout
Average, min, max and time from start of readout (in ROLL mode; instrument in HOLD)
Min, max and time from start of readout (in RECORDER mode; instrument in HOLD)
Harmonics values in POWER QUALITY mode.
Dual vertical lines Peak-peak, time distance and reciprocal time distance readout
Average, min, max and time distance readout (in ROLL mode; instrument in HOLD)
Dual horizontal lines High, low and peak-peak readout
Rise or fall time Transition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only 
possible in single channel mode)
Accuracy As oscilloscope accuracy
 
Recorder
The recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B).
The results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples.
Meter readings
Measurement Speed Maximum 2 measurement/s
Record Size (min, max, average) 2 M readings for 1 channel
Recorded Time Span 2 weeks
Maximum number of events 1024
Waveform record
Maximum sample rate 400 K sample/s
Size Internal memory 400 M samples Recorded Time
Span internal memory 15 minutes at 500 μs/div
11 hours at 20 ms/div
Record Size SD card 1.5 G samples
Recorded Time Span SD card 11 hours at 500 μs/div
14 days at 20 ms/div
Maximum number of events 64
 
Power Quality (125B only)
Readings Watt, VA, var, PF, DPF, Hz
Watt, VA, var ranges (auto) 250 W to 250 MW, 625 MW, 1.56 GW
When selected: total (% r) ±(2% + 6 counts)
When selected: fundamental (% f) ±(4% + 4 counts)
DPF 0.00 to 1.00
PF 0.00 to 1.00, ±0.04
Frequency range 10.0 Hz to 15.0 kHz
40.0 Hz to 70.0 Hz
Number of Harmonics DC to 51
Readings / Cursor readings 
(fundamental 40 Hz to 70 Hz)
Vrms / Arms /Watt Each harmonic from fundamental maybe selected for individual readings
Includes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)
 
BusHealth tester (Fluke 125B only)
Type Subtype Protocol
AS-i NEN-EN50295
CAN ISO-11898
Interbus S RS-422 EIA-422
Modbus RS-232 RS-232/EIA-232
RS-485 RS-485/EIA-485
Foundation Fieldbus H1 61158 type 1, 31.25 kBit
Profibus DP EIA-485
PA 61158 type 1
 
Miscellaneous
Display Type 5.7-inch color active matrix TFT
Resolution 640 x 480 pixels
Waveform Display Vertical 10 div of 40 pixels
Horizontal 12 div of 40 pixels
Power External Via Power Adapter BC430
Input voltage 10 V DC to 21 V DC
Power consumption 5 W typical
Input connector 5 mm jack
Internal Via Battery Pack BP290
Battery power Rechargeable Li-Ion 10.8 V
Operating time 7 hours with 50% backlight brightness
Charging time 4 hours with test tool off,  7 hours with test tool on
Allowable ambient temp 0 to 40 °C (32 to 104 °F) during charging
Memory Internal memory can store 20 data sets  (screen waveform and setup) Micro SD card slot with optional SD card  (max size of 32 GB)
Mechanical Size 259 x 132 x 55 mm 
(10.2 x 5.2 x 2.15 in)
Weight 1.4 kg (3.2 lb) including battery pack
Interface Optically isolated Transfer screen copies (bitmaps), settings and data
USB to PC/laptop OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®.
Optional WiFi adapter Fast transfer of screen copies (bitmaps), settings and data to PC/laptop, tablet, smartphone, etc. A USB port is provided for attaching the WiFi dongle. Do not use the USB port with a cable for safety reasons.
 
Environmental
Environmental MIL-PRF-28800F, Class 2
Temperature Battery Operation 0 to 40 °C (32 to 104 °F)
Power Adapter Operation 0 to 50 °C (32 to 122 °F)
Storage -20 to 60 °C (-4 to 140 °F)
Humidity (Operating) @ 0 to 10 °C (32 to 50 °F) Non-condensing
@ 10 to 30 °C (50 to 86 °F) 95%
@ 30 to 40 °C (86 to 104 °F) 75%
@ 40 to 50 °C (104 to 122 °F) 45%
Storage @ -20 to 60 °C (-4 to 140 °F) Non-condensing
Altitude Operating at 3 km (10,000 feet) CAT III 600 V
Operating at 2 km (6,600 feet) CAT IV 600 V
Storage 12 km (40,000 feet)
EMC electromagnetic compatibility International IEC 61326-1: Industrial, CISPR 11:  Group 1, Class A
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Wireless radio with adapter Frequency range 2412 MHz to 2462 MHz
Output power <100 mW
Enclosure protection IP51, ref: EN/IEC60529
Safety General IEC 61010-1: Pollution Degree 2
Measurement IEC 61010-2-033: CAT IV 600 V/CAT III 750 V
Max. input voltage input A and B Direct on input or with leads 600 Vrms CAT IV for derating
With Banana-to-BNC Adapter BB120 600 Vrms for derating
Max. floating voltage from any terminal to ground 600 Vrms Cat IV, 750 Vrms up to 400 Hz

 

Models: Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes

FLUKE-123B/NA
Fluke 123B/S Industrial ScopeMeter® Hand-Held Oscilloscope (20 MHz)

Includes:

  • Fluke 123B Hand-Held Oscilloscope
  • Shielded Test Leads with Black Ground Leads
  • Test Lead Black (for Grounding)
  • Hook Clips (red, blue)
  • Banana-to-BNC Adapters (black, x1)
  • USB Angled Adapter
  • WiFi USB Adapter*
  • Switch Mode Power Supply, Adapter/Battery Charger
  • Rechargeable Li-ion Battery Pack
  • Soft Carrying Case
  • Magnetic Hanger
  • FlukeView® ScopeMeter® Software for Windows®
  • Screen Protector
FLUKE-123B/NA/S
Fluke 123B Industrial ScopeMeter® Hand-Held Oscilloscope (20 MHz)

Includes:

    • Fluke 123B Hand-Held Oscilloscope
    • Shielded Test Leads with Black Ground Leads
    • Test Lead Black (for Grounding)
    • Hook Clips (red, blue)
    • Banana-to-BNC Adapters (black, x1)
    • USB Angled Adapter
    • WiFi USB Adapter*
    • Switch Mode Power Supply, Adapter/Battery Charger
    • Rechargeable Li-ion Battery Pack
    FLUKE-124B/NA
    Fluke 124B Industrial ScopeMeter® Hand-Held Oscilloscope (40 MHz)

    Includes:

    • Fluke 124B Hand-Held Oscilloscope
    • Shielded Test Leads with Black Ground Leads
    • Test Lead Black (for Grounding)
    • Hook Clips (red, blue)
    • Banana-to-BNC Adapters (black, x1)
    • 10:1 Voltage Probe
    • USB Angled Adapter
    • WiFi USB Adapter*
    • Switch Mode Power Supply, Adapter/Battery Charger
    • Rechargeable Li-ion Battery Pack
    FLUKE-124B/NA/S
    Fluke 124B/S Industrial ScopeMeter® Hand-Held Oscilloscope (40 MHz)

    Includes:

    • Fluke 124B Hand-Held Oscilloscope
    • Shielded Test Leads with Black Ground Leads
    • Test Lead Black (for Grounding)
    • Hook Clips (red, blue)
    • Banana-to-BNC Adapters (black, x1)
    • 10:1 Voltage Probe
    • USB Angled Adapter
    • WiFi USB Adapter*
    • Switch Mode Power Supply, Adapter/Battery Charger
    • Rechargeable Li-ion Battery Pack
    • Soft Carrying Case
    • Magnetic Hanger
    • FlukeView® ScopeMeter® Software for Windows®
    • Screen Protector
    FLUKE-125B/NA
    Fluke 125B Industrial ScopeMeter® Hand-Held Oscilloscope (40 MHz)

    Includes:

    • Fluke 125B Hand-Held Oscilloscope
    • Shielded Test Leads with Black Ground Leads
    • Test Lead Black (for Grounding)
    • Hook Clips (red, blue)
    • Banana-to-BNC Adapters (black, x1)
    • 10:1 Voltage Probe
    • i400s AC Current Clamp
    • USB Angled Adapter
    • WiFi USB Adapter*
    • Switch Mode Power Supply, Adapter/Battery Charger
    • Rechargeable Li-ion Battery Pack
    FLUKE-125B/NA/S
    Fluke 125B/S Industrial ScopeMeter® Hand-Held Oscilloscope (40 MHz)

    Includes:

    • Fluke 125B Hand-Held Oscilloscope
    • Shielded Test Leads with Black Ground Leads
    • Test Lead Black (for Grounding)
    • Hook Clips (red, blue)
    • Banana-to-BNC Adapters (black, x1)
    • 10:1 Voltage Probe
    • i400s AC Current Clamp
    • USB Angled Adapter
    • WiFi USB Adapter*
    • Switch Mode Power Supply, Adapter/Battery Charger
    • Rechargeable Li-ion Battery Pack
    • Soft Carrying Case
    • Magnetic Hanger
    • FlukeView® ScopeMeter® Software for Windows®
    • Screen Protector

    Resources: Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes

    Manuals

    Application Notes

    Shipping This Item Ships from Fremantle, Perth, Western Australia
    Please allow 2 - 10 days for your order to arrive.

    Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

    Returns are easy.

    simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

    Description

    (item no. 4755680, 4755927, 4755768, 4756005, 4755841, 4756087)

    Key features

    • Dual-input digital oscilloscope and multimeter in a ScopeMeter® test tool
    • Available with a 40 MHz or 20 MHz oscilloscope bandwidth
    • Features Connect-and-View™ trigger simplicity for hands-off operation
    • Includes IntellaSet™ technology to automatically and intelligently adjust numerical readout based on measured signal
    • Provides a dual-input waveform and meter reading recorder for trending data over extended periods

    Product overview: Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes

    Simplified testing, more insight and faster electro-mechanical troubleshooting

    The compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.

    *Not all models are available in all countries. Check with your local Fluke representative.

    Other useful features:

    • Features two 5,000-count True-RMS digital multimeters
    • Offers recorder Event Detect to capture elusive intermittent signals on repetitive waveforms up to 4 kHz
    • Comes with shielded test leads for oscilloscope, resistance and continuity measurements
    • Features resistance, continuity, diode, and capacitance meter measurements
    • Performs power measurements (W, VA, VAR, PF, DPF, Hz)
    • Measures voltage, current and power harmonics
    • Check Industrial networks with BusHealth physical layer tests against defined reference levels (125B only)
    • Allows you to save and recall data and instrument setups
    • Includes FlukeView® ScopeMeter® software for Windows®
    • Features a rugged design to withstand 3g vibration, 30g shock, and rated IP51 according to EN/IEC60529
    • Runs on a Li-Ion rechargeable battery providing seven-hours operation (with four-hour charge time)
    • Features highest safety rating in the industry: safety rated for CAT IV 600 V

    Specifications: Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes

    Oscilloscope mode
    Vertical
    Frequency response - dc coupled Without probes and test leads (with BB120) 123B: dc to 20 MHz (-3 dB)
    124B and 125B: dc to 40 MHz (-3 dB)
    With STL120-IV 1:1 shielded test leads DC to 12.5 MHz (-3 dB) / dc to 20 MHz (-6 dB)
    With VP41 10:1 Probe 123B: dc to 20MHz (-3 dB)
    124B and 125B: dc to 40 MHz (-3 dB)
    Frequency response - ac coupled (lf roll off) Without probes and test leads <10 Hz (-3 dB)
    With STL120-IV 1:1 shielded test leads <10 Hz (-3 dB)
    With VP41 10:1 Probe <10 Hz (-3 dB)
    Rise time, excluding probes, 
    test leads
    123B <17.5 ns
    124B and 125B <8.75 ns
    Input impedance Without probes and test leads 1 MΩ//20 pF
    With BB120 1 MΩ//24 pF
    With STL120-IV 1:1 shielded test leads 1 MΩ//230 pF
    With VP41 10:1 Probe 5 MΩ//15.5 pF
    Sensitivity 5 mV to 200 V/div
    Analog bandwidth limiter 10 kHz
    Display modes A, -A, B, -B
    Max. input voltage A and B Direct, with test leads, or with VP41 Probe 600 Vrms Cat IV, 750 Vrms maximum voltage.
    With BB120 600 Vrms
    Max. floating voltage, from any terminal to ground 600 Vrms Cat IV, 750 Vrms up to 400Hz
    Horizontal
    Scope modes Normal, Single, Roll
    Ranges (normal) Equivalent sampling 123B: 20 ns to 500 ns/div,
    124B and 125B: 10 ns to 500 ns/div
    Real time sampling 1 μs to 5 s/div
    Single (real time) 1 μs to 5 s/div
    Roll (real time) 1s to 60 s/div
    Sampling rate (for both channels simultaneously) Equivalent sampling (repetitive signals) Up to 4 GS/s
    Real time sampling 1 μs to 60 s/div 40 MS/s
     
    Trigger
    Screen update Free run, on trigger
    Source A, B
    Sensitivity A and B @ DC to 5 MHz 0.5 divisions or 5 mV
    @ 40 MHz 123B: 4 divisions
    124B and 125B: 1.5 divisions
    @ 60 MHz 123B: N/A
    124B and 125B: 4 divisions
    Slope Positive, negative
     
    Advanced scope functions
    Display modes Normal Captures up to 25 ns glitches and displays analog-like persistence waveform
    Smooth Suppresses noise from a waveform
    Glitch off Does not capture glitches between samples
    Envelope Records and displays the minimum and maximum of waveforms over time
    Auto set (Connect-and-View™) Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.
     
    Dual input meter
    The accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C.
    Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe  uncertainty +1%. More than one waveform period must be visible on the screen.
     
    Input A and input B
    DC voltage (VDC)
    Ranges 500 mV, 5 V, 50 V, 500 V, 750 V
    Accuracy ±(0.5% +5 counts)
    Common mode rejection (CMRR) >100 dB @ dc, >60 dB @ 50, 60, or 400 Hz
    Full scale reading 5000 counts
    True-rms voltages (V ac and V ac+dc)
    Ranges 500 mV, 5 V, 50 V, 500 V, 750 V
    Accuracy for 5% to 100% of range (DC coupled) DC to 60 Hz (V ac+dc) ±(1% +10 counts)
    1 Hz to 60 Hz (V ac) ±(1% +10 counts)
    Accuracy for 5% to 100% of range (AC or dc coupled) 60 Hz to 20 kHz ±(2.5% +15 counts)
    DC rejection (only VAC) >50 dB
    Common mode rejection (CMRR) >100 dB @ dc
    >60 dB @ 50, 60, or 400 Hz
    Full scale reading 5000 counts, reading is independent of any signal crest factor.
    Peak
    Modes Max peak, Min peak, or pk-to-pk
    Ranges 500 mV, 5 V, 50 V, 500 V, 2200 V
    Accuracy Accuracy Max peak or Min peak 5% of full scale
    Accuracy Peak-to-Peak 10% of full scale
    Full scale reading 500 counts
    Frequency (Hz)
    Ranges 123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz
    124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz
    Frequency range 15 Hz (1 Hz) to 50 MHz in continuous autoset
    Accuracy @1 Hz to 1 MHz ±(0.5% +2 counts)
    Full scale reading 10,000 counts
    RPM
    Max reading 50.00 kRPM
    Accuracy ±(0.5% +2 counts)
    Duty cycle (PULSE)
    Range 2% to 98%
    Frequency range 15 Hz (1 Hz) to 30 MHz in continuous autoset
    Pulse width (PULSE)
    Frequency range 15 Hz (1 Hz) to 30 MHz in continuous autoset
    Full scale reading 1000 counts
    Amperes (AMP)
    With current clamp Ranges Same as V dc, V ac, V ac+dc, or PEAK
    Scale factors 0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA
    Accuracy Same as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty)
    Temperature (TEMP) with optional temperature probe
    Range 200 °C/div (200 °F/div)
    Scale factor 1 mV/°C and 1 mV/°F
    Accuracy As V dc (add temp. probe uncertainty)
    Decibel (dB)
    0 dBV 1 V
    0 dBm (600 Ω /50 Ω) 1 mW referenced to 600 Ω or 50 Ω
    dB on V dc, V ac, or Vac+dc
    Full scale reading 1000 counts
    Crest factor (CREST)
    Range 1 to 10
    Full scale reading 90 Counts
    Phase
    Modes A to B, B to A
    Range 0 to 359 degrees
    Resolution 1 degree
    Power (125B only)
    Configurations 1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only)
    Power factor (PF) Ratio between watts and VA range - 0.00 to 1.00
    Watt RMS reading of multiplying corresponding samples of input A (volts) and input B (amperes)
    Full scale reading 999 counts
    VA Vrms x Arms
    Full scale reading 999 counts
    VA reactive (var) √((VA)2-W2)
    Full scale reading 999 counts
    Vpwm
    Purpose To measure on pulse width modulated signals, like motor drive inverter outputs
    Principle Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency
    Accuracy As Vrms for sinewave signals
     
    Input A to common
    Ohm (Ω)
    Ranges 123B and 124B 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
    125B 50 Ω, 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
    Accuracy ±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts)
    Full scale reading 50 Ω to 5 MΩ - 5000 counts, 30 MΩ - 3000 counts
    Measurement current 0.5 mA to 50 nA, decreases with increasing ranges
    Open circuit voltage <4 V
    Continuity (Cont)
    Beep <(30 Ω ±5 Ω) in 50 Ω range
    Measurement current 0.5 mA
    Detection of shorts of ≥1 ms
    Diode
    Measurement voltage @0.5 mA >2.8 V
    @open circuit <4 V
    Measurement current 0.5 mA
    Polarity + on input A, - on COM
    Capacitance (CAP)
    Ranges 50 nF, 500 nF, 5 μF, 50 μF, 500 μF
    Full scale reading 5000 counts
    Measurement current 500 nA to 0.5 mA, increases with increasing ranges
     
    Advanced meter functions
    Zero Set Set actual value to reference
    AutoHold (on A) Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.
    Fixed decimal point Activated by using attenuation keys
     
    Cursor Readout (124B and 125B)
    Sources A, B
    Single vertical line Average, min and max readout
    Average, min, max and time from start of readout (in ROLL mode; instrument in HOLD)
    Min, max and time from start of readout (in RECORDER mode; instrument in HOLD)
    Harmonics values in POWER QUALITY mode.
    Dual vertical lines Peak-peak, time distance and reciprocal time distance readout
    Average, min, max and time distance readout (in ROLL mode; instrument in HOLD)
    Dual horizontal lines High, low and peak-peak readout
    Rise or fall time Transition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only 
    possible in single channel mode)
    Accuracy As oscilloscope accuracy
     
    Recorder
    The recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B).
    The results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples.
    Meter readings
    Measurement Speed Maximum 2 measurement/s
    Record Size (min, max, average) 2 M readings for 1 channel
    Recorded Time Span 2 weeks
    Maximum number of events 1024
    Waveform record
    Maximum sample rate 400 K sample/s
    Size Internal memory 400 M samples Recorded Time
    Span internal memory 15 minutes at 500 μs/div
    11 hours at 20 ms/div
    Record Size SD card 1.5 G samples
    Recorded Time Span SD card 11 hours at 500 μs/div
    14 days at 20 ms/div
    Maximum number of events 64
     
    Power Quality (125B only)
    Readings Watt, VA, var, PF, DPF, Hz
    Watt, VA, var ranges (auto) 250 W to 250 MW, 625 MW, 1.56 GW
    When selected: total (% r) ±(2% + 6 counts)
    When selected: fundamental (% f) ±(4% + 4 counts)
    DPF 0.00 to 1.00
    PF 0.00 to 1.00, ±0.04
    Frequency range 10.0 Hz to 15.0 kHz
    40.0 Hz to 70.0 Hz
    Number of Harmonics DC to 51
    Readings / Cursor readings 
    (fundamental 40 Hz to 70 Hz)
    Vrms / Arms /Watt Each harmonic from fundamental maybe selected for individual readings
    Includes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)
     
    BusHealth tester (Fluke 125B only)
    Type Subtype Protocol
    AS-i NEN-EN50295
    CAN ISO-11898
    Interbus S RS-422 EIA-422
    Modbus RS-232 RS-232/EIA-232
    RS-485 RS-485/EIA-485
    Foundation Fieldbus H1 61158 type 1, 31.25 kBit
    Profibus DP EIA-485
    PA 61158 type 1
     
    Miscellaneous
    Display Type 5.7-inch color active matrix TFT
    Resolution 640 x 480 pixels
    Waveform Display Vertical 10 div of 40 pixels
    Horizontal 12 div of 40 pixels
    Power External Via Power Adapter BC430
    Input voltage 10 V DC to 21 V DC
    Power consumption 5 W typical
    Input connector 5 mm jack
    Internal Via Battery Pack BP290
    Battery power Rechargeable Li-Ion 10.8 V
    Operating time 7 hours with 50% backlight brightness
    Charging time 4 hours with test tool off,  7 hours with test tool on
    Allowable ambient temp 0 to 40 °C (32 to 104 °F) during charging
    Memory Internal memory can store 20 data sets  (screen waveform and setup) Micro SD card slot with optional SD card  (max size of 32 GB)
    Mechanical Size 259 x 132 x 55 mm 
    (10.2 x 5.2 x 2.15 in)
    Weight 1.4 kg (3.2 lb) including battery pack
    Interface Optically isolated Transfer screen copies (bitmaps), settings and data
    USB to PC/laptop OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®.
    Optional WiFi adapter Fast transfer of screen copies (bitmaps), settings and data to PC/laptop, tablet, smartphone, etc. A USB port is provided for attaching the WiFi dongle. Do not use the USB port with a cable for safety reasons.
     
    Environmental
    Environmental MIL-PRF-28800F, Class 2
    Temperature Battery Operation 0 to 40 °C (32 to 104 °F)
    Power Adapter Operation 0 to 50 °C (32 to 122 °F)
    Storage -20 to 60 °C (-4 to 140 °F)
    Humidity (Operating) @ 0 to 10 °C (32 to 50 °F) Non-condensing
    @ 10 to 30 °C (50 to 86 °F) 95%
    @ 30 to 40 °C (86 to 104 °F) 75%
    @ 40 to 50 °C (104 to 122 °F) 45%
    Storage @ -20 to 60 °C (-4 to 140 °F) Non-condensing
    Altitude Operating at 3 km (10,000 feet) CAT III 600 V
    Operating at 2 km (6,600 feet) CAT IV 600 V
    Storage 12 km (40,000 feet)
    EMC electromagnetic compatibility International IEC 61326-1: Industrial, CISPR 11:  Group 1, Class A
    Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
    USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
    Wireless radio with adapter Frequency range 2412 MHz to 2462 MHz
    Output power <100 mW
    Enclosure protection IP51, ref: EN/IEC60529
    Safety General IEC 61010-1: Pollution Degree 2
    Measurement IEC 61010-2-033: CAT IV 600 V/CAT III 750 V
    Max. input voltage input A and B Direct on input or with leads 600 Vrms CAT IV for derating
    With Banana-to-BNC Adapter BB120 600 Vrms for derating
    Max. floating voltage from any terminal to ground 600 Vrms Cat IV, 750 Vrms up to 400 Hz

     

    Models: Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes

    FLUKE-123B/NA
    Fluke 123B/S Industrial ScopeMeter® Hand-Held Oscilloscope (20 MHz)

    Includes:

    • Fluke 123B Hand-Held Oscilloscope
    • Shielded Test Leads with Black Ground Leads
    • Test Lead Black (for Grounding)
    • Hook Clips (red, blue)
    • Banana-to-BNC Adapters (black, x1)
    • USB Angled Adapter
    • WiFi USB Adapter*
    • Switch Mode Power Supply, Adapter/Battery Charger
    • Rechargeable Li-ion Battery Pack
    • Soft Carrying Case
    • Magnetic Hanger
    • FlukeView® ScopeMeter® Software for Windows®
    • Screen Protector
    FLUKE-123B/NA/S
    Fluke 123B Industrial ScopeMeter® Hand-Held Oscilloscope (20 MHz)

    Includes:

      • Fluke 123B Hand-Held Oscilloscope
      • Shielded Test Leads with Black Ground Leads
      • Test Lead Black (for Grounding)
      • Hook Clips (red, blue)
      • Banana-to-BNC Adapters (black, x1)
      • USB Angled Adapter
      • WiFi USB Adapter*
      • Switch Mode Power Supply, Adapter/Battery Charger
      • Rechargeable Li-ion Battery Pack
      FLUKE-124B/NA
      Fluke 124B Industrial ScopeMeter® Hand-Held Oscilloscope (40 MHz)

      Includes:

      • Fluke 124B Hand-Held Oscilloscope
      • Shielded Test Leads with Black Ground Leads
      • Test Lead Black (for Grounding)
      • Hook Clips (red, blue)
      • Banana-to-BNC Adapters (black, x1)
      • 10:1 Voltage Probe
      • USB Angled Adapter
      • WiFi USB Adapter*
      • Switch Mode Power Supply, Adapter/Battery Charger
      • Rechargeable Li-ion Battery Pack
      FLUKE-124B/NA/S
      Fluke 124B/S Industrial ScopeMeter® Hand-Held Oscilloscope (40 MHz)

      Includes:

      • Fluke 124B Hand-Held Oscilloscope
      • Shielded Test Leads with Black Ground Leads
      • Test Lead Black (for Grounding)
      • Hook Clips (red, blue)
      • Banana-to-BNC Adapters (black, x1)
      • 10:1 Voltage Probe
      • USB Angled Adapter
      • WiFi USB Adapter*
      • Switch Mode Power Supply, Adapter/Battery Charger
      • Rechargeable Li-ion Battery Pack
      • Soft Carrying Case
      • Magnetic Hanger
      • FlukeView® ScopeMeter® Software for Windows®
      • Screen Protector
      FLUKE-125B/NA
      Fluke 125B Industrial ScopeMeter® Hand-Held Oscilloscope (40 MHz)

      Includes:

      • Fluke 125B Hand-Held Oscilloscope
      • Shielded Test Leads with Black Ground Leads
      • Test Lead Black (for Grounding)
      • Hook Clips (red, blue)
      • Banana-to-BNC Adapters (black, x1)
      • 10:1 Voltage Probe
      • i400s AC Current Clamp
      • USB Angled Adapter
      • WiFi USB Adapter*
      • Switch Mode Power Supply, Adapter/Battery Charger
      • Rechargeable Li-ion Battery Pack
      FLUKE-125B/NA/S
      Fluke 125B/S Industrial ScopeMeter® Hand-Held Oscilloscope (40 MHz)

      Includes:

      • Fluke 125B Hand-Held Oscilloscope
      • Shielded Test Leads with Black Ground Leads
      • Test Lead Black (for Grounding)
      • Hook Clips (red, blue)
      • Banana-to-BNC Adapters (black, x1)
      • 10:1 Voltage Probe
      • i400s AC Current Clamp
      • USB Angled Adapter
      • WiFi USB Adapter*
      • Switch Mode Power Supply, Adapter/Battery Charger
      • Rechargeable Li-ion Battery Pack
      • Soft Carrying Case
      • Magnetic Hanger
      • FlukeView® ScopeMeter® Software for Windows®
      • Screen Protector

      Resources: Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes

      Manuals

      Application Notes

      Shipping

      Shipping This item ships to

      Delivery & Returns

      Please allow 2 - 10 days for your order to arrive.

      Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

      Returns are easy.

      simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

      Reviews

      Fluke 120B Series Industrial Scopemeter Hand Held Oscilloscope

      Fluke 120B Series Industrial Scopemeter Hand Held Oscilloscope

      $3,048.00

      Part Number

      Fluke 120B Series Industrial Scopemeter Hand Held Oscilloscope

      Fluke 120B Series Industrial Scopemeter Hand Held Oscilloscope

      $3,048.00

      Part Number

      Recently viewed products