Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Laserman closed April 25, Thursday for Anzac Day Public Holiday! Call Us +61 8 9335 1718
FREE Shipping For Purchases Over $250 within Australia

Fluke FLUKE-572-2 Dual Laser IR Thermometer (item no. 4328074)

SKU: 4328074
$2,499.00
Checkout Secure
Need more info? Call us +61 8 9335 1718

6Great reasons to buy from us:

  • Image of If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.

    30 Days Return

    If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.
  • Image of Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

    Returns are Easy

    Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
  • Image of In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.

    Best Price Guarantee

    In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.
  • Image of We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.

    We guarantee your satisfaction

    We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.
  • Image of Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.

    100% Safe & Secure

    Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.
  • Image of Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

    Best Laser Warranties in the Business

    Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

(item no. 4328074)

Product overview

Fluke-572-2 High Temperature Infrared Thermometer measures temperatures up to 900°C

This high-temperature infrared thermometer is built for use in high-temperature industrial environments. It has a straight-forward user interface and soft-key menus, making even complex measurements easier. Quickly navigate and adjust emissivity, start data logging, or turn on and off alarms, with just a few pushes of a button.

Features

  • 60:1 distance to spot ratio with dual laser sighting for fast, accurate targeting
  • Multi-language interface (user select)
  • Current Temperature plus MAX, MIN, DIF, AVG temperature displays
  • Compatible with standard mini-connector K-type thermocouples
  • Adjustable emissivity and predefined emissivity table
  • Infrared and thermocouple temperature on backlit display
  • Last reading Hold (20 seconds)
  • High and low temperature alarm
  • Data storage and review (99 data sets)
  • Tripod mount
  • 12 or 24 hour clock
  • USB 2.0 computer interface cable
  • FlukeView® Forms Documenting Software
  • Two-year warranty

Applications

  • Utilities
  • Mining and Minerals
  • Oil and Gas

Specifications: 572-2 High Temperature Infrared Thermometer

Infrared Measurements
Infrared temperature range -30°C to 900°C (-22°F to 1652°F)
IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C) ≥ 0°C: ± 1°C or ± 1% of the reading, whichever is greater
≥ -10°C to < 0°C: ±2°C
< -10°C: ±3°C
≥ 32°F: ± 2°F or ± 1% of the reading, whichever is greater
≥ 14°F to < 32°F: ±4°F
< 14°F: ±6°F
IR repeatability ±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Display resolution 0.1°C / 0.1°F
Distance: Spot 60:1 (calculated at 90% energy)
Minimum spot size 19 mm
Laser sighting Offset dual laser, output < 1 mW
Spectral response 8 μm to 14 μm
Response time (95%) < 500 ms
Emissivity Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials
Contact Measurements
K-type thermocouple input temperature range -270°C to 1372°C (-454°F to 2501°F)
K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C) < -40°C: ±(1°C + 0.2° / 1°C)
≥ -40°C: ±1% or 1°C, whichever is greater
< -40°F: ±(2°F + 0.2° / 1°F)
≥ -40°F: ±1% or 2°F, whichever is greater
K-type thermocouple 0.1°C / 0.1°F
K-type thermocouple repeatability ±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Measurement Options
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Switchable celsius and fahrenheit Yes
Backlight Two levels, normal and extra bright for darker environments
Probe input K-type thermocouple simultaneous display of probe and IR temperature
Trigger lock Yes
Data storage 99 points
Display Dot matrix 98 x 96 pixels with function menus
Communication USB 2.0
K-Type Thermocouple Specifications
Measurement range (bead probe) -40°C to 260°C (-40°F to 500°F)
Accuracy ±1.1°C (±2.0°F) from 0°C to 260°C (32°F to 500°F). Typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)
Cable length 1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination
General Specifications
Safety and compliance IEC 60825-1
FDA Laser Class II
IEC 61326-1
CE Complaint
CMC # 01120009
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-4°F to 140°F)
Relative humidity 10% to 90% RH non-condensing up to 30°C (86°F)
Operating altitude 2000 meters above mean sea level
Weight 0.322 kg (0.7099 lb)
Power 2 AA batteries
Battery life 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle (thermometer continuously on)

 

Models: 572-2 High Temperature Infrared Thermometer

Fluke 572-2
Fluke 572-2 High-Temperature Infrared Thermometer

Includes:

  • K-type thermocouple bead probe
  • Durable hard case
  • USB 2.0 computer interface cable

Resources: 572-2 High Temperature Infrared Thermometer

Manuals

Brochures

Shipping This Item Ships from Fremantle, Perth, Western Australia
Please allow 2 - 10 days for your order to arrive.

Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

Returns are easy.

simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

Description

(item no. 4328074)

Product overview

Fluke-572-2 High Temperature Infrared Thermometer measures temperatures up to 900°C

This high-temperature infrared thermometer is built for use in high-temperature industrial environments. It has a straight-forward user interface and soft-key menus, making even complex measurements easier. Quickly navigate and adjust emissivity, start data logging, or turn on and off alarms, with just a few pushes of a button.

Features

  • 60:1 distance to spot ratio with dual laser sighting for fast, accurate targeting
  • Multi-language interface (user select)
  • Current Temperature plus MAX, MIN, DIF, AVG temperature displays
  • Compatible with standard mini-connector K-type thermocouples
  • Adjustable emissivity and predefined emissivity table
  • Infrared and thermocouple temperature on backlit display
  • Last reading Hold (20 seconds)
  • High and low temperature alarm
  • Data storage and review (99 data sets)
  • Tripod mount
  • 12 or 24 hour clock
  • USB 2.0 computer interface cable
  • FlukeView® Forms Documenting Software
  • Two-year warranty

Applications

  • Utilities
  • Mining and Minerals
  • Oil and Gas

Specifications: 572-2 High Temperature Infrared Thermometer

Infrared Measurements
Infrared temperature range -30°C to 900°C (-22°F to 1652°F)
IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C) ≥ 0°C: ± 1°C or ± 1% of the reading, whichever is greater
≥ -10°C to < 0°C: ±2°C
< -10°C: ±3°C
≥ 32°F: ± 2°F or ± 1% of the reading, whichever is greater
≥ 14°F to < 32°F: ±4°F
< 14°F: ±6°F
IR repeatability ±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Display resolution 0.1°C / 0.1°F
Distance: Spot 60:1 (calculated at 90% energy)
Minimum spot size 19 mm
Laser sighting Offset dual laser, output < 1 mW
Spectral response 8 μm to 14 μm
Response time (95%) < 500 ms
Emissivity Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials
Contact Measurements
K-type thermocouple input temperature range -270°C to 1372°C (-454°F to 2501°F)
K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C) < -40°C: ±(1°C + 0.2° / 1°C)
≥ -40°C: ±1% or 1°C, whichever is greater
< -40°F: ±(2°F + 0.2° / 1°F)
≥ -40°F: ±1% or 2°F, whichever is greater
K-type thermocouple 0.1°C / 0.1°F
K-type thermocouple repeatability ±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Measurement Options
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Switchable celsius and fahrenheit Yes
Backlight Two levels, normal and extra bright for darker environments
Probe input K-type thermocouple simultaneous display of probe and IR temperature
Trigger lock Yes
Data storage 99 points
Display Dot matrix 98 x 96 pixels with function menus
Communication USB 2.0
K-Type Thermocouple Specifications
Measurement range (bead probe) -40°C to 260°C (-40°F to 500°F)
Accuracy ±1.1°C (±2.0°F) from 0°C to 260°C (32°F to 500°F). Typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)
Cable length 1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination
General Specifications
Safety and compliance IEC 60825-1
FDA Laser Class II
IEC 61326-1
CE Complaint
CMC # 01120009
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-4°F to 140°F)
Relative humidity 10% to 90% RH non-condensing up to 30°C (86°F)
Operating altitude 2000 meters above mean sea level
Weight 0.322 kg (0.7099 lb)
Power 2 AA batteries
Battery life 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle (thermometer continuously on)

 

Models: 572-2 High Temperature Infrared Thermometer

Fluke 572-2
Fluke 572-2 High-Temperature Infrared Thermometer

Includes:

  • K-type thermocouple bead probe
  • Durable hard case
  • USB 2.0 computer interface cable

Resources: 572-2 High Temperature Infrared Thermometer

Manuals

Brochures

Shipping

Shipping This item ships to

Delivery & Returns

Please allow 2 - 10 days for your order to arrive.

Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

Returns are easy.

simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

Reviews

Fluke FLUKE-572-2 Dual Laser IR Thermometer (item no. 4328074)

Fluke FLUKE-572-2 Dual Laser IR Thermometer (item no. 4328074)

$2,499.00
Fluke FLUKE-572-2 Dual Laser IR Thermometer (item no. 4328074)

Fluke FLUKE-572-2 Dual Laser IR Thermometer (item no. 4328074)

$2,499.00

Recently viewed products