Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Laserman closed April 25, Thursday for Anzac Day Public Holiday! Call Us +61 8 9335 1718
FREE Shipping For Purchases Over $250 within Australia

Fluke 5609 Secondary PRT with Calibration Options, 100 OHM (1/4 X 12 INCH)

SKU: 3056569
$2,483.00
Checkout Secure
Need more info? Call us +61 8 9335 1718

6Great reasons to buy from us:

  • Image of If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.

    30 Days Return

    If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.
  • Image of Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

    Returns are Easy

    Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
  • Image of In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.

    Best Price Guarantee

    In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.
  • Image of We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.

    We guarantee your satisfaction

    We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.
  • Image of Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.

    100% Safe & Secure

    Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.
  • Image of Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

    Best Laser Warranties in the Business

    Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

(item no. 3056569, 3056578, 3056584, 3056591, 3056600, 3056617, 3056621, 3056639, 3100973, 3100986, 3376776)

PRODUCT OVERVIEW: 5608 AND 5609

The 5608 comes with a one-eighth inch (3.18 mm) diameter sheath in lengths of 9 inches or 12 inches. The 5609 comes with a one-quarter inch (6.35 mm) diameter sheath in lengths of 12 inches, 15 inches, and 20 inches; or with a 6 mm diameter in lengths of 300 mm, 400 mm, or 500 mm.

When looking for improved response time and reduced stem effect in shallow immersion, look for small diameter probes, because the measurement error called stem effect is caused by the diameter of the stem rather than the length of the stem.

Both of these probes have Inconel™ sheaths and are made using a special manufacturing process, giving them great precision over a wide temperature range. The sensors for these probes are reference-grade platinum and feature four-wire connections with less noisy measurements than two-wire counterparts.

As standard, each probe includes its resistance value at the triple point of water. If calibration is desired, you can order a NVLAP-accredited calibration from our laboratory; lab code 200348-0. On the report of calibration, you’ll get the test data and the ITS90 calibration coefficients that you can easily input into any Fluke Calibration thermometer. If you order your probe with a smart connector. 

FEATURES

  • 5608: –200 °C to 500 °C (80 mm minimum immersion)
  • 5609: –200 °C to 670 °C (100 mm minimum immersion)
  • ± 0.01 short-term stability
  • Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0
  • Dry-well reference with 90 ° bend

  

SPECIFICATIONS: 5608 AND 5609

Specifications
Temperature range
5608: –200 °C to 500 °C
5609: –200 °C to 670 °C
Nominal resistance at 0.01 °C
100 Ω ± 0.5 Ω
Temperature Coefficient
0.0039250 Ω/Ω/°C
Accuracy [1]
See footnote
Short-term repeatability[2]
± 0.01 °C at 0.010 °C
± 0.02 °C at max temp
Drift[3]
± 0.01 °C at 0.010 °C
± 0.02 °C at max temp
Hysteresis
± 0.01 °C maximum
Sensor length
30 mm ± 5 mm (1.2 in ± 0.2 in)
Sensor location
3 mm ± 1 mm from tip (0.1 in ± 0.1 in)
Sheath material
Inconel™ 600
Minimum insulation resistance
5608: 500 MΩ at 23 °C, 20 MΩ at 500 °C
5609: 500 MΩ at 23 °C, 10 MΩ at 670 °C
Transition junction dimensions
71 mm x 12.5 mm (2.8 in x 0.49 in)
Minimum immersion length[4] (<5 mK error)
5608: 80 mm (3.1 in)
5609: 100 mm (3.9 in)
Maximum immersion length
305 mm (12 in)
Response time[5]
5608: 9 seconds typical
5609: 12 seconds typical
Self heating (in 0 °C bath)
5608: 75 mW/°C
5609: 50 mW/°C
Lead-wire cable type
Teflon,™ 24 AWG
Lead-wire length
1.8 m (6 ft)
Lead-wire temperature range
–50 °C to 250 °C
Calibration
Calibration not included; NVLAP-accredited calibration optional, lab code 200348-0. Please see calibration uncertainty table and its explanation of changeable uncertainties.

 

 

 

Shipping This Item Ships from Fremantle, Perth, Western Australia
Please allow 2 - 10 days for your order to arrive.

Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

Returns are easy.

simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

Description

(item no. 3056569, 3056578, 3056584, 3056591, 3056600, 3056617, 3056621, 3056639, 3100973, 3100986, 3376776)

PRODUCT OVERVIEW: 5608 AND 5609

The 5608 comes with a one-eighth inch (3.18 mm) diameter sheath in lengths of 9 inches or 12 inches. The 5609 comes with a one-quarter inch (6.35 mm) diameter sheath in lengths of 12 inches, 15 inches, and 20 inches; or with a 6 mm diameter in lengths of 300 mm, 400 mm, or 500 mm.

When looking for improved response time and reduced stem effect in shallow immersion, look for small diameter probes, because the measurement error called stem effect is caused by the diameter of the stem rather than the length of the stem.

Both of these probes have Inconel™ sheaths and are made using a special manufacturing process, giving them great precision over a wide temperature range. The sensors for these probes are reference-grade platinum and feature four-wire connections with less noisy measurements than two-wire counterparts.

As standard, each probe includes its resistance value at the triple point of water. If calibration is desired, you can order a NVLAP-accredited calibration from our laboratory; lab code 200348-0. On the report of calibration, you’ll get the test data and the ITS90 calibration coefficients that you can easily input into any Fluke Calibration thermometer. If you order your probe with a smart connector. 

FEATURES

  • 5608: –200 °C to 500 °C (80 mm minimum immersion)
  • 5609: –200 °C to 670 °C (100 mm minimum immersion)
  • ± 0.01 short-term stability
  • Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0
  • Dry-well reference with 90 ° bend

  

SPECIFICATIONS: 5608 AND 5609

Specifications
Temperature range
5608: –200 °C to 500 °C
5609: –200 °C to 670 °C
Nominal resistance at 0.01 °C
100 Ω ± 0.5 Ω
Temperature Coefficient
0.0039250 Ω/Ω/°C
Accuracy [1]
See footnote
Short-term repeatability[2]
± 0.01 °C at 0.010 °C
± 0.02 °C at max temp
Drift[3]
± 0.01 °C at 0.010 °C
± 0.02 °C at max temp
Hysteresis
± 0.01 °C maximum
Sensor length
30 mm ± 5 mm (1.2 in ± 0.2 in)
Sensor location
3 mm ± 1 mm from tip (0.1 in ± 0.1 in)
Sheath material
Inconel™ 600
Minimum insulation resistance
5608: 500 MΩ at 23 °C, 20 MΩ at 500 °C
5609: 500 MΩ at 23 °C, 10 MΩ at 670 °C
Transition junction dimensions
71 mm x 12.5 mm (2.8 in x 0.49 in)
Minimum immersion length[4] (<5 mK error)
5608: 80 mm (3.1 in)
5609: 100 mm (3.9 in)
Maximum immersion length
305 mm (12 in)
Response time[5]
5608: 9 seconds typical
5609: 12 seconds typical
Self heating (in 0 °C bath)
5608: 75 mW/°C
5609: 50 mW/°C
Lead-wire cable type
Teflon,™ 24 AWG
Lead-wire length
1.8 m (6 ft)
Lead-wire temperature range
–50 °C to 250 °C
Calibration
Calibration not included; NVLAP-accredited calibration optional, lab code 200348-0. Please see calibration uncertainty table and its explanation of changeable uncertainties.

 

 

 

Shipping

Shipping This item ships to

Delivery & Returns

Please allow 2 - 10 days for your order to arrive.

Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

Returns are easy.

simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

Reviews

Fluke 5609 Secondary PRT with Calibration Options, 100 OHM (1/4 X 12 INCH)

Fluke 5609 Secondary PRT with Calibration Options, 100 OHM (1/4 X 12 INCH)

$2,483.00
Fluke 5609 Secondary PRT with Calibration Options, 100 OHM (1/4 X 12 INCH)

Fluke 5609 Secondary PRT with Calibration Options, 100 OHM (1/4 X 12 INCH)

$2,483.00

Recently viewed products