Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Laserman closed April 25, Thursday for Anzac Day Public Holiday! Call Us +61 8 9335 1718
FREE Shipping For Purchases Over $250 within Australia

Fluke Solar Tools Kit with 393 FC Clamp Meter, Irradiance Meter and Solar Test Leads Bundle

SKU: 5337401 
$2,293.00
Checkout Secure
Need more info? Call us +61 8 9335 1718

6Great reasons to buy from us:

  • Image of If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.

    30 Days Return

    If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.
  • Image of Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

    Returns are Easy

    Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
  • Image of In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.

    Best Price Guarantee

    In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.
  • Image of We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.

    We guarantee your satisfaction

    We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.
  • Image of Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.

    100% Safe & Secure

    Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.
  • Image of Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

    Best Laser Warranties in the Business

    Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

Product overview: Solar Tools Kit with 393 FC Clamp Meter, Irradiance Meter and Solar Test Leads

Key features

  • Measure safely with CAT III 1500 V rated clamp meter
  • Thin jaw for access to cables in crowded combiner boxes
  • Work efficiently with dc power measurement, audio polarity and visual continuity
  • Measure solar irradiance, ambient and PV module temperature, array orientation and tilt angles
  • MC4 test lead sets are designed for use with solar clamp meters that accept 4mm banana plugs, rated to CAT III 1000 V / CAT IV 600 V

The 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is an industrial clamp meter designed for solar photovoltaic (PV) installation technicians and maintenance professionals who work in high voltage dc environments. Safely connect the MC4 test leads to the clamp meter to validate voltage and current from individual panels or a series of panels in a PV array. The inline capabilities of the MC4 PVLEAD3 leads allow the system to remain online and generating power while testing without needing to pierce the line. Use the IRR1-SOL to obtain the amount of solar irradiance necessary to calculate the IV curve of the power output. Validate that the panel or string of panels are outputting the correct voltage.

Key functions of the solar clamp meter, irradiance meter and MC4 test leads:

  • View voltage and current simultaneously with the meter's dual display
  • IP54 rated meter, ideal for work outdoors including PV panel testing
  • DC power measurement, showing readings in kVA
  • Logging and reporting of test results via Fluke Connect software
  • Make instantaneous measurements to determine the watts per square meter solar irradiation, required by IEC 62446-1 standard
  • MC4 leads comply to IEC / EN 61010-031

The world's first CAT III 1500 V true-RMS solar clamp meter

 

Fluke IRR1-SOL Irradiance Meter

 

 

Specifications: Fluke 393 FC CAT III 1500 V True-rms Solar Clamp Meter

General      
Maximum voltage between any Terminal and Earth Ground    
AC 1000 V    
DC 1500 V    
Batteries 2 AA IEC LR6 alkaline    
Display Dual display with backlight    
Automatic Power Off 20 minutes    
Electrical      
Accuracy      
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
Temperature Coefficients Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
AC Current: Jaw      
Range 999.9 A    
Resolution 0.1 A    
Accuracy 2 % + 5 digits (10 Hz to 100 Hz)  
  2.5 % + 5 digits (100 Hz to 500 Hz)  
Crest Factor (50/60 Hz) 2.5 @600.0 A    
  3.0 @500.0 A    
  1.42 @999.9 A    
  Add 2 % for C.F. >2    
AC Current: Flexible Current Probe      
Range 999.9 A    
  2500 A    
Resolution 0.1 A (≤999.9 A)    
  1 A (≤2500 A)    
Accuracy 3 % RD + 5 digits (10 Hz to 500 Hz)  
Crest Factor (50/60Hz) 2.5 @1400 A    
  3.0 @1100 A    
  1.42@2500 A    
  Add 2 % for C.F. >2    
Position Sensitivity      
NEC symbol
Distance from Optimum i2500-10 Flex i2500-18 Flex Error
A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ±0.5 %
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ±1.0 %
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
       
DC Current      
Range 999.9 A    
Resolution 0.1 A    
Accuracy 2 % RD + 5 digits[1]    
  [1] When using the ZERO (B) function to compensate for offsets.
AC Voltage      
Range 600.0 V    
  1000 V    
Resolution 0.1 V (≤600.0 V)    
  1 V (≤1000 V)    
Accuracy 1 % RD + 5 digits (20 Hz to 500 Hz)  
DC Voltage      
Range 600.0 V    
  1500 V    
Resolution 0.1 V (≤600.0 V)    
  1 V (≤1500 V)    
Accuracy 1 % RD + 5 digits    
mV dc      
Range 500.0 mV    
Resolution 0.1 mV    
Accuracy 1 % RD + 5 digits    
Amps Frequency: Jaw      
Range 5.0 Hz to 500.0 Hz    
Resolution 0.1 Hz    
Accuracy 0.5 % RD + 5 digits    
Trigger Level 5 Hz to 10 Hz, ≥10 A    
  10 Hz to 100 Hz, ≥5 A    
  100 Hz to 500 Hz, ≥10 A    
Amps Frequency: Flexible Current Probe      
Range 5.0 Hz to 500.0 Hz    
Resolution 0.1 Hz    
Accuracy 0.5 % RD + 5 digits    
Trigger Level 5 Hz to 20 Hz, ≥25 A    
  20 Hz to 100 Hz, ≥20 A    
  100 Hz to 500 Hz, ≥25 A    
Voltage Frequency      
Range 5.0 Hz to 500.0 Hz    
Resolution 0.1 Hz    
Accuracy 0.5 % RD + 5 digits    
Trigger Level 5 Hz to 20 Hz, ≥5 V    
  20 Hz to 100 Hz, ≥5 V    
  100 Hz to 500 Hz, ≥10 V    
DC Power      
Range 600.0 kVA (600.0 V dc range)    
  1500 kVA (1500 V dc range)    
Resolution 0.1 kVA    
  1 kVA    
Accuracy 2 % RD + 2.0 kVA    
  2 % RD + 20 kVA    
Resistance      
Range 600.0 Ω    
  6000 Ω    
  60.00 kΩ    
Resolution 0.1 Ω (≤600.0 Ω)    
  1 Ω (≤6000 Ω)    
  0.01 kΩ (≤60.00 kΩ)    
Accuracy 1 % RD + 5 digits    
Capacitance      
Range 100.0 μF    
  1000 μF    
Resolution 0.1 μF (≤100.0 μF)    
  1 μF (≤1000 μF)    
Accuracy 1 % RD + 5 digits    
Inrush Trigger Level 5 A    
Mechanical      
Size (L x W x H) 281 mm x 84 mm x 49 mm    
Weight (with batteries) 520 g    
Jaw Opening 34 mm    
Flexible Current Probe Diameter 7.5 mm    
Flexible Current Probe Cable Length      
(head to electronics connector) 1.8 m    
Environmental      
Operating Temperature -10 °C to 50 °C    
Storage Temperature -40 °C to 60 °C    
Operating Humidity Non condensing (<10°C)    
  ≤90 % RH (at 10 °C to 30 °C)    
  ≤75 % RH (at 30 °C to 40 °C)    
  ≤45 % RH (at 40 °C to 50 °C)    
Operating Altitude 2000 m    
Storage Altitude 12 000 m    
Ingress Protection (IP) Rating IEC 60529: IP54 non-operating    
Electromagnetic Compatibility (EMC)      
International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
  Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC) Class A equipment (Industrial Broadcast & Communications Equipment)
  Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety      
General IEC 61010-1, Pollution Degree 2  
Measurement IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V  
  IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V  
Wireless Radio      
Radio frequency certification FCC ID: T68-FBLE, IC: 6627A-FBLE  
Wireless Radio Frequency Range 2400 MHz to 2483.5 MHz    
Output Power <100 mW    
SIMPLIFIED EU DECLARATION OF CONFORMITY    
Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
The full text of the EU declaration is available at the following Internet address:    
www.fluke.com/en-us/declaration-of-conformity      

 

Specifications: Fluke Solar Irradiance Meter

Irradiance
Measuring Range 0 to 1400 W/m²
Resolution 1 W/m²
Measuring Accuracy ± (5 % + 5 Digit)
Temperature Measurement
Measuring range (°C) -22 °F to 212 °F (-30 °C to 100 °C)
Resolution 0.2 °F (0.1 °C) / 1 °F @>100 °F
Measuring Accuracy ±2 °F (±1 °C) @ 14 °F to 167 °F (-10 °C to 75 °C),
±4 °F (±2 °C) @ -22 °F to 14 °F (-30 °C to -10 °C) and 167 °F to 212 °F (75 °C to 100 °C)
Note: Temperature measurement response time: ~30 sec.
Inclination Angle
Measuring Range -90° to +90°
Resolution 0.1°
Measuring Accuracy ± 1.5°@ -50° to +50°, ±2.5° @ -85° to -50° and +50° to +85°, ±3.5° @ -90° to -85° and +85° to +90°
Compass
Measuring Range 0° to 360°
Resolution
Measuring Accuracy ±7°
Note:
a) Measurements valid for device inclination between -20° and +20° to horizontal. Outside that range on LCD will be shown "---".
b) Result is referred to magnetic north.
Temperature
Operating Temperature IRR1-SOL -20 °C to 50 °C (humidity <80%), noncondensing
Operating Temperature 80PR-IRR -30 °C to +100 °C
Storage Temperature -30 °C to 60 °C (humidity <80%)
Altitude 0 m to max. 2000 m
Electromagnetic Compatibility (EMC)
International IEC 61326-1: Portable Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Protection
IP Protection IP40
Power Supply & Battery Life
Batteries 4 AA Alkaline Batteries
Battery Life (typical) 50 hours (≤9000 readings)
Auto Power Off 30 minutes
Dimensions
L x W x H 5.90 x 3.14 x 1.37 in (150 x 80 x 35 mm)
Weight 0.5 lb (231 g)


Specifications: Pomona PVLEAD1 and PVLEAD3 MC4 Solar Clamp Test Lead Set

  PVLEAD1 PVLEAD3
MC4 to 4mm Test Lead Set MC4 Solar Clamp Meter Test Lead Set
Contact Brass, Nickel Plated Brass, Nickel Plated
Length 60” 36”, 12”
Voltage CAT III 1000V, CAT III 1000V,
CAT IV 600V CAT IV 600V
Current 20 amp 20 amp
Standards IEC 61010-031 IEC 61010-031

 

FLK-393-IRR-PVLEAD

Includes:
  • Fluke 393 FC CAT III 1500 V TRMS clamp meter
  • Test leads, CAT III 1500 V rated, right angle plugs, with safety caps
  • iFlex 18 inch flexible current probe
  • TPAK magnetic hanging strap
  • Premium carrying case
  • 3-year warranty
  • FLK-IRR1-SOL Solar Irradiance Meter
  • FLK80PR-IRR External Temperature Probe with Suction Cup
  • C250 Carrying Case with Shoulder Strap
  • (4) AA Alkaline Batteries (installed)
  • User Manual
  • Pomona PVLEAD1 MC4 to 4 mm Test Lead Set
  • Pomona PVLEAD3 MC4 Solar Clamp Test Lead Set

Manual

DataSheet

Shipping This Item Ships from Fremantle, Perth, Western Australia
Please allow 2 - 10 days for your order to arrive.

Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

Returns are easy.

simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

Description

Product overview: Solar Tools Kit with 393 FC Clamp Meter, Irradiance Meter and Solar Test Leads

Key features

  • Measure safely with CAT III 1500 V rated clamp meter
  • Thin jaw for access to cables in crowded combiner boxes
  • Work efficiently with dc power measurement, audio polarity and visual continuity
  • Measure solar irradiance, ambient and PV module temperature, array orientation and tilt angles
  • MC4 test lead sets are designed for use with solar clamp meters that accept 4mm banana plugs, rated to CAT III 1000 V / CAT IV 600 V

The 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is an industrial clamp meter designed for solar photovoltaic (PV) installation technicians and maintenance professionals who work in high voltage dc environments. Safely connect the MC4 test leads to the clamp meter to validate voltage and current from individual panels or a series of panels in a PV array. The inline capabilities of the MC4 PVLEAD3 leads allow the system to remain online and generating power while testing without needing to pierce the line. Use the IRR1-SOL to obtain the amount of solar irradiance necessary to calculate the IV curve of the power output. Validate that the panel or string of panels are outputting the correct voltage.

Key functions of the solar clamp meter, irradiance meter and MC4 test leads:

  • View voltage and current simultaneously with the meter's dual display
  • IP54 rated meter, ideal for work outdoors including PV panel testing
  • DC power measurement, showing readings in kVA
  • Logging and reporting of test results via Fluke Connect software
  • Make instantaneous measurements to determine the watts per square meter solar irradiation, required by IEC 62446-1 standard
  • MC4 leads comply to IEC / EN 61010-031

The world's first CAT III 1500 V true-RMS solar clamp meter

 

Fluke IRR1-SOL Irradiance Meter

 

 

Specifications: Fluke 393 FC CAT III 1500 V True-rms Solar Clamp Meter

General      
Maximum voltage between any Terminal and Earth Ground    
AC 1000 V    
DC 1500 V    
Batteries 2 AA IEC LR6 alkaline    
Display Dual display with backlight    
Automatic Power Off 20 minutes    
Electrical      
Accuracy      
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
Temperature Coefficients Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
AC Current: Jaw      
Range 999.9 A    
Resolution 0.1 A    
Accuracy 2 % + 5 digits (10 Hz to 100 Hz)  
  2.5 % + 5 digits (100 Hz to 500 Hz)  
Crest Factor (50/60 Hz) 2.5 @600.0 A    
  3.0 @500.0 A    
  1.42 @999.9 A    
  Add 2 % for C.F. >2    
AC Current: Flexible Current Probe      
Range 999.9 A    
  2500 A    
Resolution 0.1 A (≤999.9 A)    
  1 A (≤2500 A)    
Accuracy 3 % RD + 5 digits (10 Hz to 500 Hz)  
Crest Factor (50/60Hz) 2.5 @1400 A    
  3.0 @1100 A    
  1.42@2500 A    
  Add 2 % for C.F. >2    
Position Sensitivity      
NEC symbol
Distance from Optimum i2500-10 Flex i2500-18 Flex Error
A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ±0.5 %
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ±1.0 %
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
       
DC Current      
Range 999.9 A    
Resolution 0.1 A    
Accuracy 2 % RD + 5 digits[1]    
  [1] When using the ZERO (B) function to compensate for offsets.
AC Voltage      
Range 600.0 V    
  1000 V    
Resolution 0.1 V (≤600.0 V)    
  1 V (≤1000 V)    
Accuracy 1 % RD + 5 digits (20 Hz to 500 Hz)  
DC Voltage      
Range 600.0 V    
  1500 V    
Resolution 0.1 V (≤600.0 V)    
  1 V (≤1500 V)    
Accuracy 1 % RD + 5 digits    
mV dc      
Range 500.0 mV    
Resolution 0.1 mV    
Accuracy 1 % RD + 5 digits    
Amps Frequency: Jaw      
Range 5.0 Hz to 500.0 Hz    
Resolution 0.1 Hz    
Accuracy 0.5 % RD + 5 digits    
Trigger Level 5 Hz to 10 Hz, ≥10 A    
  10 Hz to 100 Hz, ≥5 A    
  100 Hz to 500 Hz, ≥10 A    
Amps Frequency: Flexible Current Probe      
Range 5.0 Hz to 500.0 Hz    
Resolution 0.1 Hz    
Accuracy 0.5 % RD + 5 digits    
Trigger Level 5 Hz to 20 Hz, ≥25 A    
  20 Hz to 100 Hz, ≥20 A    
  100 Hz to 500 Hz, ≥25 A    
Voltage Frequency      
Range 5.0 Hz to 500.0 Hz    
Resolution 0.1 Hz    
Accuracy 0.5 % RD + 5 digits    
Trigger Level 5 Hz to 20 Hz, ≥5 V    
  20 Hz to 100 Hz, ≥5 V    
  100 Hz to 500 Hz, ≥10 V    
DC Power      
Range 600.0 kVA (600.0 V dc range)    
  1500 kVA (1500 V dc range)    
Resolution 0.1 kVA    
  1 kVA    
Accuracy 2 % RD + 2.0 kVA    
  2 % RD + 20 kVA    
Resistance      
Range 600.0 Ω    
  6000 Ω    
  60.00 kΩ    
Resolution 0.1 Ω (≤600.0 Ω)    
  1 Ω (≤6000 Ω)    
  0.01 kΩ (≤60.00 kΩ)    
Accuracy 1 % RD + 5 digits    
Capacitance      
Range 100.0 μF    
  1000 μF    
Resolution 0.1 μF (≤100.0 μF)    
  1 μF (≤1000 μF)    
Accuracy 1 % RD + 5 digits    
Inrush Trigger Level 5 A    
Mechanical      
Size (L x W x H) 281 mm x 84 mm x 49 mm    
Weight (with batteries) 520 g    
Jaw Opening 34 mm    
Flexible Current Probe Diameter 7.5 mm    
Flexible Current Probe Cable Length      
(head to electronics connector) 1.8 m    
Environmental      
Operating Temperature -10 °C to 50 °C    
Storage Temperature -40 °C to 60 °C    
Operating Humidity Non condensing (<10°C)    
  ≤90 % RH (at 10 °C to 30 °C)    
  ≤75 % RH (at 30 °C to 40 °C)    
  ≤45 % RH (at 40 °C to 50 °C)    
Operating Altitude 2000 m    
Storage Altitude 12 000 m    
Ingress Protection (IP) Rating IEC 60529: IP54 non-operating    
Electromagnetic Compatibility (EMC)      
International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
  Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC) Class A equipment (Industrial Broadcast & Communications Equipment)
  Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety      
General IEC 61010-1, Pollution Degree 2  
Measurement IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V  
  IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V  
Wireless Radio      
Radio frequency certification FCC ID: T68-FBLE, IC: 6627A-FBLE  
Wireless Radio Frequency Range 2400 MHz to 2483.5 MHz    
Output Power <100 mW    
SIMPLIFIED EU DECLARATION OF CONFORMITY    
Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
The full text of the EU declaration is available at the following Internet address:    
www.fluke.com/en-us/declaration-of-conformity      

 

Specifications: Fluke Solar Irradiance Meter

Irradiance
Measuring Range 0 to 1400 W/m²
Resolution 1 W/m²
Measuring Accuracy ± (5 % + 5 Digit)
Temperature Measurement
Measuring range (°C) -22 °F to 212 °F (-30 °C to 100 °C)
Resolution 0.2 °F (0.1 °C) / 1 °F @>100 °F
Measuring Accuracy ±2 °F (±1 °C) @ 14 °F to 167 °F (-10 °C to 75 °C),
±4 °F (±2 °C) @ -22 °F to 14 °F (-30 °C to -10 °C) and 167 °F to 212 °F (75 °C to 100 °C)
Note: Temperature measurement response time: ~30 sec.
Inclination Angle
Measuring Range -90° to +90°
Resolution 0.1°
Measuring Accuracy ± 1.5°@ -50° to +50°, ±2.5° @ -85° to -50° and +50° to +85°, ±3.5° @ -90° to -85° and +85° to +90°
Compass
Measuring Range 0° to 360°
Resolution
Measuring Accuracy ±7°
Note:
a) Measurements valid for device inclination between -20° and +20° to horizontal. Outside that range on LCD will be shown "---".
b) Result is referred to magnetic north.
Temperature
Operating Temperature IRR1-SOL -20 °C to 50 °C (humidity <80%), noncondensing
Operating Temperature 80PR-IRR -30 °C to +100 °C
Storage Temperature -30 °C to 60 °C (humidity <80%)
Altitude 0 m to max. 2000 m
Electromagnetic Compatibility (EMC)
International IEC 61326-1: Portable Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Protection
IP Protection IP40
Power Supply & Battery Life
Batteries 4 AA Alkaline Batteries
Battery Life (typical) 50 hours (≤9000 readings)
Auto Power Off 30 minutes
Dimensions
L x W x H 5.90 x 3.14 x 1.37 in (150 x 80 x 35 mm)
Weight 0.5 lb (231 g)


Specifications: Pomona PVLEAD1 and PVLEAD3 MC4 Solar Clamp Test Lead Set

  PVLEAD1 PVLEAD3
MC4 to 4mm Test Lead Set MC4 Solar Clamp Meter Test Lead Set
Contact Brass, Nickel Plated Brass, Nickel Plated
Length 60” 36”, 12”
Voltage CAT III 1000V, CAT III 1000V,
CAT IV 600V CAT IV 600V
Current 20 amp 20 amp
Standards IEC 61010-031 IEC 61010-031

 

FLK-393-IRR-PVLEAD

Includes:
  • Fluke 393 FC CAT III 1500 V TRMS clamp meter
  • Test leads, CAT III 1500 V rated, right angle plugs, with safety caps
  • iFlex 18 inch flexible current probe
  • TPAK magnetic hanging strap
  • Premium carrying case
  • 3-year warranty
  • FLK-IRR1-SOL Solar Irradiance Meter
  • FLK80PR-IRR External Temperature Probe with Suction Cup
  • C250 Carrying Case with Shoulder Strap
  • (4) AA Alkaline Batteries (installed)
  • User Manual
  • Pomona PVLEAD1 MC4 to 4 mm Test Lead Set
  • Pomona PVLEAD3 MC4 Solar Clamp Test Lead Set

Manual

DataSheet

Shipping

Shipping This item ships to

Delivery & Returns

Please allow 2 - 10 days for your order to arrive.

Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

Returns are easy.

simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

Reviews

Fluke Solar Tools Kit with 393 FC Clamp Meter, Irradiance Meter and Solar Test Leads Bundle

Fluke Solar Tools Kit with 393 FC Clamp Meter, Irradiance Meter and Solar Test Leads Bundle

$2,293.00
Fluke Solar Tools Kit with 393 FC Clamp Meter, Irradiance Meter and Solar Test Leads Bundle

Fluke Solar Tools Kit with 393 FC Clamp Meter, Irradiance Meter and Solar Test Leads Bundle

$2,293.00

Recently viewed products